Seagate Video 3.5 HDD Product Manual, Rev. B 17
www.seagate.com
2.11 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance
when subjected to the radio frequency (RF) environments defined in the following table:
2.12 Reliability - Annualized Failure Rate
The product will achieve an Annualized Failure Rate (AFR) of 0.55% when operated in an environment of ambient air
temperatures of 25°C. Operation at temperatures outside the specifications shown in
Section 2.9 may increase the
product AFR. AFR is a population statistics that is not relevant to individual units.
• AFR specifications are based on the following assumptions for consumer electronics environments:
• 8760 power-on-hours per year
• 10,000 average motor start/stop cycles per year
• Operations at nominal voltages
• Temperatures outside the specifications in
Section 2.9 may reduce the product reliability.
• Normal I/O duty cycle for consumer electronics environments. Operation at excessive I/O duty cycle may degrade
product reliability.
The consumer electronics environment of power-on-hours, temperature, and I/O duty cycle affect the product AFR. The
AFR will be degraded if used in an enterprise application.
2.13 Warranty
To determine the warranty for a specific drive, use a web browser to access the following web page:
http://www.seagate.com/support/warranty-and-replacements/
From this page, click on “Is my Drive under Warranty”. Users will be asked to provide the drive serial number, model
number (or part number) and country of purchase. The system will display the warranty information for the drive.
Table 4 Radio frequency environments
Test Description
Performance
Level
Reference
standard
Electrostatic discharge Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B EN61000-4-2: 95
Radiated RF immunity
80MHz to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 200Hz
A
EN61000-4-3: 96
ENV 50204: 95
Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on external I/O B EN61000-4-4: 95
Surge immunity ± 1 kV differential, ± 2 kV common, AC mains B EN61000-4-5: 95
Conducted RF immunity 150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz sine A EN61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94