INSTALLATION
MANUAL
Product:
Document #:
Rev:
Page:
SEAKEEPER 1
90519
1
21 of 29
Section 3: COOLING INSTALLATION
3.0 INTRODUCTION
Reference Drawings and Documents:
90512 Seakeeper 1 Cooling Water Schematic
90594 Seakeeper 1 Cable Block Diagram
TB_90191Seawater Cooling Pump Recommendations
30331 DC Seawater Pump, Seakeeper 1 Assembly
The Seakeeper 1 is shipped with the cooling circuit filled and ready for use. The Seakeeper 1 requires
connection to a raw water pump, referred to as the seawater pump, to cool the closed loop cooling
circuit on the unit. The required seawater flow through the Seakeeper 1 heat exchanger is between
2 4 GPM (7.6 15.2 LPM), under all vessel operating conditions. Prior to operation, confirmation of
glycol level is required.
Seakeeper offers a compatible self-priming DC Seawater Pump (P/N 30331) that is prewired for the
Seakeeper 1 Installation and covered under the standard Seakeeper warranty. See Drawing No.
30331, DC Seawater Pump, Seakeeper 1 Assembly
for details and the Seakeeper Options and
Accessories Price List for pricing information.
Figure 1: Seakeeper 1 Cooling Components