INSTALLATION
MANUAL
Section 4: INSTALLATION REQUIREMENTS
4.0 INTRODUCTION
The Installation Requirements section outlines the components and tools needed for the Seakeeper
1 installation that are not included within the scope of supply.
4.1 REQUIRED SUPPLIES FOR SEAKEEPER INSTALLATION
Table 1 outlines the customer-supplied components required for the Seakeeper 1 installation:
Table 1: Components and Supplies Required for Seakeeper 1 Installation
Installation
Manual
Reference
1 Spreader bar for lifting the Seakeeper 1 1 1.3.2 P/N 11766 Mechanical
2 Seakeeper 1 Foundation 1 1.4 Dwg 90559 Mechanical
3 Seakeeper 1 Fixture Kit 1 1.4.1 P/N 90517 Mechanical
4 Threaded insert: M14-2 x 1.5DIA (21mm) 4 1.4.2 Dwg 90516 Mechanical
5 Seakeeper 1 Bolt-In Kit 1 1.4.3 P/N 90599 Mechanical
6 Marine Sealant AR 1.4.3 Dwg 90516 Mechanical
7 Anti-Seize AR 1.4.3 Dwg 90516 Mechanical
8 Conductor, Marine, 2 AWG, Red (Cable 1: B+ Positive) AR 2.2.2 Dwg 90511 Electrical
9 Conductor, Marine, 2 AWG, Black (Cable 2: B- Negative) AR 2.2.2 Dwg 90511 Electrical
10 Circuit Breaker, 80A (Cable 1) 1 2.2.2 Dwg 90511 Electrical
11 Battery Isolator Switch (Cable 1 / Cable 7) 1 2.2.2 Dwg 90511 Electrical
12
Seawater Pump, 12VDC, 15A max
Optional: DC Seawater Pump Assembly (prewired)
1 2.3.1
Dwg 90512,
P/N 30331
Electrical /
Cooling
13 Circuit Breaker corresponding to pump rating (Cable 7) 1 2.3.2 Dwg 90511 Electrical
14
Deutsch DT Series 2-pin Receptacle – Female (Cable 5)
*Not required with Seakeeper Seawater Pump (30331)
1 2.3.3 Dwg 90511 Electrical
15 Conductor, Marine, 4 AWG, Green (Cable 6: Ground) AR 2.4.1 Dwg 90470 Electrical
16 Compatible MFD or Seakeeper 5” Touch Display Kit 1 2.5.1
TB 90573,
P/N 90600
Electrical
17
MFD Connection Cable, M12 D Code, 4-Pin: Garmin /
Raymarine / Simrad (Optional)
1 2.5.2
Electrical
18 NMEA 2000 Backbone with compatible GPS Signal 1 2.6 Dwg 90511 Electrical
19
Through-hull fittings (1 high-speed pick-up / 1
overboard discharge)
2 3.1 Dwg 90512 Cooling
20
Seawater Strainer *Included with Seakeeper Seawater
Pump (30331)
1 3.2 Dwg 90512 Cooling
21 Seacock Valve 1 3.2 Dwg 90512 Cooling
22 ½” ID Seawater Hose AR 3.2 Dwg 90512 Cooling
23 Hose Clamps 1/2" (13 mm) fittings (2 per connection) 8 3.2 Dwg 90512 Cooling
•
AR = As Required
•
Dwg = Drawing
•
P/N = Seakeeper Part Number