5. OPERATION
5.1. PRIMARY CHECKS
5.1.1. Checkthattheinletfilterisclean;pumpdeliveryandpressurewillbereducedifblocked.Neverusethemachinewithoutafilter(whichis
fitted at the end of the supply hose.
5.1.2. Ensure that the water supply, hose and gun are correctly connected, and that air can circulate around the washer freely.
5.2. OPERATING THE UNIT
5.2.1. Holdthespraygunfirmlytocounteracttherecoilcausedbythehighpressurejetofthewater.Beforeswitchingon,ensurethatthelance
isnotdirectedatpeople,objectsoranimalspriortobeingdirectedattheobjecttobecleaned.
5.2.2. Tostartspraying,holddownthesafetybutton(fig.2)anddepressthetrigger(fig.2)fully.Whenthetriggerisreleased,themotorwillswitch
off automatically.
5.2.3. Spraypatternadjustmentcanbemadebyrotatingthespraynozzleheadtooneof6possiblestyles.
5.2.4. Whenusingthesoapdispenserunit:NOTE:Thisdevicehasbeendesignedtobeusedwithaneutral,biodegradablecleaningagent.
Otherdetergentsorchemicalsubstancescouldimpairthesafetyofthepressurecleaneranddamageit.Suchdamagetothe
equipmentisnotcoveredbytheguarantee.
5.3. WHEN WASHING IS COMPLETED
5.3.1. Wipethemachinecleananddry.
5.3.2. Removethebattery.
5.3.3. Disconnect the water supply hose.
5.3.4. Dischargeanyresidualpressureintheunitbypressingthetriggeruntilnomorewatercomesoutofthenozzle.
WARNING!Failuretodischargepressurecouldresultinpersonalinjury.
5.3.5. Store in a clean, safe, dry, frost free and childproof location.
WARNING! – Risk of Hand Arm Vibration Injury.
This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.
ThistoolissubjecttothevibrationtestingsectionoftheMachineryDirective2006/42/EC.
Thistoolistobeoperatedinaccordancewiththeseinstructions.
Measured vibration emission value (a): .........1.339 m/s²
Uncertainty value (k):...........................1.5 m/s²
Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a
specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.
Ahealthandsafetyassessmentbytheuser(oremployer)willneedtobecarriedouttodeterminethesuitabledurationofuseforeachtool.
NB: StatedVibrationEmissionvaluesaretype-testvaluesandareintendedtobetypical.
Whilstinuse,theactualvaluewillvaryconsiderablyfromanddependonmanyfactors.
Suchfactorsinclude;theoperator,thetaskandtheinsertedtoolorconsumable.
NB:ensurethatthelengthofleaderhosesissufficienttoallowunrestricteduse,asthisalsohelpstoreducevibration.
State of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase risk of Hand Arm Vibration Syndrome.
Health surveillance.
Werecommendaprogrammeofhealthsurveillancetodetectearlysymptomsofvibrationinjurysothatmanagementprocedurescanbemodified
accordingly.
Personal protective equipment.
Wearenotawareofanypersonalprotectiveequipment(PPE)thatprovidesprotectionagainstvibrationinjurythatmayresultfromthe
uncontrolleduseofthistool.Werecommendasufficientsupplyofclothing(includinggloves)toenabletheoperatortoremainwarmanddryand
maintaingoodbloodcirculationinfingersetc.Pleasenotethatthemosteffectiveprotectionisprevention,pleaserefertotheCorrectUseand
Maintenancesectionintheseinstructions.GuidancerelatingtothemanagementofhandarmvibrationcanbefoundontheHSCwebsite
www.hse.gov.uk-Hand-ArmVibrationatWork.
Original Language Version
© Jack Sealey Limited
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycleunwantedmaterialsinsteadofdisposingofthemaswaste.Alltools,accessoriesandpackagingshouldbesorted,takento
arecyclingcentreanddisposedofinamannerwhichiscompatiblewiththeenvironment.Whentheproductbecomescompletely
unserviceableandrequiresdisposal,drainanyfluids(ifapplicable)intoapprovedcontainersanddisposeoftheproductandfluids
according to local regulations.
WEEE REGULATIONS
DisposeofthisproductattheendofitsworkinglifeincompliancewiththeEUDirectiveonWasteElectricalandElectronicEquipment
(WEEE).Whentheproductisnolongerrequired,itmustbedisposedofinanenvironmentallyprotectiveway.Contactyourlocalsolid
waste authority for recycling information.
BATTERY REMOVAL
UndertheWasteBatteriesandAccumulatorsRegulations2009,JackSealeyLtdarerequiredtoinformpotentialpurchasersofproducts
containingbatteries(asdefinedwithintheseregulations),thattheyareregisteredwithValpak’sregisteredcompliancescheme.Jack
SealeyLtdBatteriesProducerRegistrationNumber(BPRN)isBPRN00705.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important:NoLiabilityisacceptedforincorrectuseofthisproduct.
Warranty:Guaranteeis12monthsfrompurchasedate,proofofwhichisrequiredforanyclaim.