TROLLEY GEARED 1 & 3TONNE
MODEL NO’S: PT1000G.V2, PT3000G.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. CONTENTS
Section 2. General.
Section 2.1 Identification
Section 2.2. Technical Data
Section 3. Safety
Section 4. Operation
Section 5. Maintenance
Section 6. Inspection/Examination
Section 7. Assembly
Section 8. Responsibilities (of the owner/operator)
Section 9. Declaration of Conformity
Section 10/11. Parts diagrams
2. GENERAL
2.1. Identification
Supplier: Sealey Power Products,
Kempson Way,
Suffolk Business Park,
Bury St Edmunds,
Suffolk, IP32 7AR.
Model No’s:
PT1000G.V2, PT3000G.V2
3. SAFETY
9 Keep trolley and beams in good working order and condition. Follow the inspection requirements as described in Section 6.
Maintenance. Take immediate action to repair or replace damaged parts by contacting your supplier. Ensure that all accessory
lifting devices are suitably certified. If damaged, remove from service immediately.
9 The trolley is designed to travel on a beam and carry a load up to the rated capacity. The capacity indicated on the trolley (see
nameplate) is the maximum safe working load which must not be exceeded.
9 Keep children and unauthorised persons away from the working area.
9 Keep working area clean and tidy, free from unrelated materials and ensure that there is adequate lighting.
Refer to
instruction
manual
Wear protective
headwear
Wear protective
gloves
Wear protective
footwear
2.2 Technical Data
Rated Capacity
a) Design Capability: Test Load 50% overload.
b) For applications see Section 3 & 4.
c) For information on parts and materials requiring specialised
repair techniques see Section 6.
d) Ambient operating temperature between -10°C and +50°C.
SEE TABLE BELOW
Model Weight
Minimum
Standard
I-Beam
Dimensions
Maximum
Distance
Between Spans:
Maximum Standard
I-Beam
Dimensions
(D X W X Web):
Maximum
Distance
Between Spans:
PT1000G.V2 17kg 125 x 75 x 5.5mm 2500mm 250 x 125 x 7.5mm 6000mm
PT3000G.V2 41kg 200 x 100 x 7.0mm 2700mm 850 x 150 x 9.0mm 4500mm
Model Capacity Test Load
Min/Max.
I Beam
Width
Min. Curve
Radius
A B C D E
PT1000G.V2 1000kg 1500kg 64-140mm 1000mm 255mm 205mm 135mm 104mm 128mm
PT3000G.V2 3000kg 4500kg 76-203mm 1500mm 344mm 250mm 180mm 150mm 200mm
PT1000G.V2, PT3000G.V2 | Issue:2(H,F) 07/03/18
Original Language Version
© Jack Sealey Limited