DIVISION 22
BASIC FIELD MANUAL
FOR
MICROWAVE HOOD COMBINATION
MODEL 721.86002010
721.86003010
721.86009010
April, 2010
MODEL 721.86002
721.86003
721.86009

Questions and Answers

  • M
    mariewoodAug 10, 2025
    What to do if the stirrer motor of my Sears 721.86009010 Microwave hood combination is not working?
    • J
      joshua53Aug 10, 2025
      If the stirrer motor is not working, check the resistance. A normal stirrer motor should measure approximately 120 to 135 ohms. An abnormal stirrer motor will measure infinite resistance.
  • C
    Crystal LucasAug 19, 2025
    How to troubleshoot a faulty turntable motor in my Sears Microwave hood combination?
    • K
      Kristen MasonAug 19, 2025
      To troubleshoot a faulty turntable motor, check its resistance. A normal motor should measure approximately 2.0 to 3.0 Kohms. An abnormal motor will measure infinite or several ohms.
  • L
    lauren62Aug 28, 2025
    What to do if the absolute humidity sensor in my Sears 721.86009010 is not working?
    • K
      Kyle PittmanAug 28, 2025
      To troubleshoot the absolute humidity sensor, check the resistance between terminals. Normal resistance should be approximately: BK-RD: 6.0 Kohms, RD-WH: 3.0 Kohms, BK-WH: 3.0 Kohms. Abnormal resistance will be infinite or approximately 0 ohm.

Summary

Safety Precautions

Service Safety Precautions

Precautions to avoid microwave energy exposure during servicing.

General Cautions for Servicing

Warnings regarding high voltage and proper service procedures.

Installation and Operation

Installation Procedures

Guidelines and precautions for installing the appliance.

Service Information

Testing Procedures

Microwave Leakage Testing

Methods and equipment for measuring microwave energy leakage.

Measurement Procedures

Instructions for measuring power output and other parameters.

Interlock Continuity Test

Continuity tests for primary, secondary, and monitor interlock switches.

Component Testing and Troubleshooting

Checkout Procedures

Troubleshooting common problems like fuse blowing.

Troubleshooting Guide

Step-by-step guide for diagnosing and resolving issues.