SEB INTERNATIONAL SERVICE Avril 2014
6. ASS defect description
Distributor position issue:
Time for distributor movment done and no
action from distributor.
Priming issue:
Pump running=5sec & vol < 10ml
Flow metter defect:
Pump running and no flow
Leakage in the water circuit during cylinder
decent:
Flow >50ml/min & vol measured>80ml
Actuator obstruction defect:
Flow <50ml/min et vol measured <25ml
Coffee circuit blocked:
After 5 secondes of disposal, flow <80ml/min
Grinder (grinds are too fine)
CTN defect:
Temperature too high or too low regarding
the heating time
Compaction head gasket
missing or defective
Ejection issue (4 times defect 13)
Cake ejection defect:
During cylinder upward, no ejection switch
impulse
Calibration defect:
Lack of gauge or switch issue
Calibration defect with empty tank or on the
second coffee test:
Wrong flow meter impulse nbr or calibration
switch issue
Calibration defect during measure of the
empty tank:
Value measured with empty tank is not
between 6 mm and 9.6 mm
Heating resistor issue:
The heating has been actuated and the
temperature has not change
Fuse wires red and/or blue
Comunication issues between Display and
power boards
Both boards are not
compatible