Model 804 17
GB
8. Servicing
Changing the batteries
When or bAtt appear in the display, you should change the batteries. You re-
quire 4 AAA-type 1.5 V batteries.
– Carefully turn over the scale so that the
base of the scale is accessible (see
Fig. 3).
– Push the battery compartment closure
towards “Battery” and open the cover.
– Remove exhausted batteries and insert
new batteries in the battery compart-
ment.
Check that the polarity is correct.
– Close the cover.
– Then turn the scale back up the right
way.
9. Technical data
Dimensions
width: 315 mm
height: 44 mm
depth: 300 mm
Height of figures 20 mm
Weight approx. 1.3 kg
Temperature range +10 °C to +40 °C
Maximum load 150 kg / 330.6 lb / 23:8 st
Minimum load 2 kg / 4.4 lb
Graduations
0 up to 150 kg 100 g
up to 330.6 lb 0.2 lb
Measurement ranges
Body fat 4.0 to 80.0 % in 0.1 % increments
Body water 4.0 to 80.0 % in 0.1 % increments
Height 100 to 220 cm in 1 cm increments
39.5 inches to 86.5 inches in 0.5 inch increments
Power supply Battery
Batteries 4 type AAA 1.5 V batteries
Weighing precision greater than ±0,6 %