SUPERCOOL-1000 rev.03
SUPERCOOL-1000
FEATURES2.
The SUPERCOOL-1000 is an electronic device
used to control the humidity level and room
temperature in livestock buildings. It allows
the user to cool the building and maintain a
specified humidity level by operating venti-
lation and mist cooling equipment. It can
control one mist cooling zone and three fan
stages. The main features of the SUPER-
COOL-1000 are as follows:
Large LCD Display The large LCD display
gives the current readings and displays the
parameters. Refer to the next section of this
manual for further information about the pa-
rameters that are shown on this display.
P i l ot L i g h ts Pilot lights indicating the state
of outputs allow the user to monitor the
operation of the system without having to
enter the building.
Removable Connectors The inputs' con-
nection is now made easier by removing the
connectors from the main board.
Manual Control The mist cooling valve
and pump can be manually activated using a
switch located on the side of the controller.
Dust Control Cycle When mist units are
not required for reducing room temperature,
they can be operated either continuously or
intermittently to reduce the level of dust in
the room.
Humidity Compensation Operating times
for mist timers can be automatically adjusted
as a function of humidity levels in the build-
ing.
Probe Inputs Up to 6 temperature probes,
1 outside temperature probe and 3 humidity
sensors can be connected to the controller
in order to obtain a more accurate reading of
the average room temperature and humidity
level.
Probe Readings Recorded For Past Days
Minimum and maximum readings from tem-
perature and humidity probes are recorded for
the current day and the past six days.
Monitoring Of Water Consumption A
pulse input is available to monitor daily wa-
ter consumption for the current day and the
past six days.
Maintenance Reminder Function A mes-
sage reminding the user to perform pump
maintenance can be signalled after the pump
has been in operation for a specified time.
Alarm Management Alarms are provided
for defective probes and other system func-
tions. Alarm states are kept in memory until
acknowledged even if an alarm situation has
been rectified.
Password Protection A password feature
can be enabled to restrict access to the con-
troller setup functions.
Backup Battery A backup battery allows
the unit to keep time in case of a power
failure.
Overload And Overvoltage Protection Re-
settable fuses are provided at low-voltage
inputs and outputs of the controller to pro-
tect its circuitry in the case of an overload
or overvoltage.
Computer Control The controller can be
connected to a computer, thus making it
possible to centralize the management of
information and diversify control strategies.
Test Mode A test mode allows you to
simulate temperature changes and verify
controller performance.