8
SUPERCOOL-1000 rev.03
SUPERCOOL-1000
5. TIME & DATE
Press 1.
7
- TIME & DATE. The current
time and date are displayed.
12:00:00 PM
01/31/200X
Press MODIFY. The hours flash on the 2.
display. Use the arrow keys to set the hours.
Press MODIFY. The minutes flash on the dis-
play. Use the arrow keys to set the minutes.
Press MODIFY once again. The seconds flash
on the display. Use the arrow keys to adjust
the seconds to the desired value.
Press MODIFY. The month flashes. Use 3.
the arrow keys to set the month. Press
MODIFY, the day flashes. Use the arrow
keys to set the day. Press MODIFY once
again, the year flashes. Use the arrow keys
to set the year.
MONITORING FUNCTIONS6.
6.1. Current Conditions
6.1.1. History
Temperature of the Probe 6.1.1.1.
Sets used by the Outputs
Press 1.
C
- CURRENT CONDITIONS.
Press the current condition down-arrow 2.
key to select the temperature reading of the
desired misting or ventilation output (Mist
T°, Fan #1-3 T°). The output's average tem-
perature is displayed. The output's active
temperature probes flash on the display.
Mist T° 80.0 °F
Pr.Act: 123456
Press on the navigation down-arrow key, 3.
today's minimum temperature, as read by the
output's probes, is displayed along with the
time and date.
Mist T° 12/04/XX
Min 79.2 12:06P
Press on the navigation down-arrow key, 4.
today's maximum temperature, as read by
the output's probes, is displayed along with
the time and date.
Mist T° 12/04/XX
Max 85.3 5:06P
Press on the navigation down-arrow key 5.
to scroll the display. The minimum and maxi-
mum readings of the output's temperature
probes are displayed for the current day and
for the past 6 days.
Press on the navigation down-arrow key 6.
again to display the current reading of the
temperature probes.
1: 84.5 2: 84.0
3: 84.0 4: 83.5