Twin Photobeam Detectors
Manual
Model # Outdoor Range Indoor Range
E-964-D390Q* 390 ft (120m) 790 ft (240m)
E-960-D290Q 290 ft (90m) 590 ft (180m)
E-960-D190Q 190 ft (60m) 390 ft (120m)
E-960-D90Q 90 ft (30m) 190 ft (60m)
* Multi-frequency version

Questions and Answers

  • R
    Robert WolfeAug 9, 2025
    Why is the alarm LED continuously lit on my SECO-LARM SLI Enforcer E-964-D390Q?
    • S
      scookAug 9, 2025
      If the Alarm LED on your SECO-LARM Security Sensors is continuously lit, it could be due to several reasons: the lenses might be out of alignment, the beams could be blocked, or the cover might be foggy or dirty. Try these solutions: * Realign the lenses. * Remove any obstacles blocking the beams. * Clean the cover.
  • R
    Russell DavisAug 14, 2025
    What to do if SECO-LARM Security Sensors have frequent false triggers?
    • D
      dbryantAug 14, 2025
      If your SECO-LARM Security Sensors are experiencing frequent false triggers due to leaves, birds, or other small objects, it could be because the sensors are too sensitive or the location is not ideal. You can try reducing the response time or changing the location of the transmitter and/or receiver.
  • L
    Lisa CannonAug 19, 2025
    Why does the receiver LED never light up on my SECO-LARM SLI Enforcer E-964-D390Q?
    • J
      Jennifer GambleAug 19, 2025
      If the Receiver LED on your SECO-LARM Security Sensors never lights up when the beam is interrupted, there are several possible causes: insufficient voltage, the beam being reflected away from the receiver, or the beams not being simultaneously interrupted. Here's what you can do: * Double-check the voltage. * Clean the cover. * Check the overall installation.
  • R
    rnicholsAug 25, 2025
    What to do if beams are interrupted but no alarm triggers on SECO-LARM SLI Enforcer E-964-D390Q Security Sensors?
    • J
      John JacksonAug 25, 2025
      If the beams are interrupted and the LED lights up, but there is no alarm trigger on your SECO-LARM Security Sensors, the alarm trigger cable may be cut, or the relay contact stuck due to overloading. Check the continuity of the wiring between the sensor and the alarm.
  • G
    Glenn KelleyAug 29, 2025
    Why does the alarm trigger become erratic in bad weather for SECO-LARM SLI Enforcer E-964-D390Q?
    • A
      Anthony WattsAug 29, 2025
      If the alarm trigger on your SECO-LARM Security Sensors becomes erratic in bad weather, it is likely due to the lenses being out of alignment. Check the overall system installation and realign the lenses if necessary.
  • S
    Sara ChambersSep 3, 2025
    How to fix a SECO-LARM Security Sensors transmitter LED that does not light?
    • A
      Adriana ArcherSep 3, 2025
      If the Transmitter LED on your SECO-LARM Security Sensors does not light, it could be due to being incorrectly wired and/or insufficient voltage. Ensure the power supply to the transmitter is 12 to 24 VAC/VDC.

SECO-LARM SLI Enforcer E-964-D390Q Specifications

General IconGeneral
Number of Beams4
IP RatingIP65
Temperature Range-13°F to 131°F (-25°C to 55°C)
Detection MethodInfrared Beam Interruption
RangeUp to 390ft (120m) outdoor
Tamper OutputForm A relay, 0.5A@24VDC
Alignment Angle±90° Horizontal, ±10° Vertical
Response Time50ms to 700ms
HousingPolycarbonate
Detection Angle±10°