EasyManua.ls Logo

Securiton SecuriFire 500 User Manual

Securiton SecuriFire 500
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Securiton AG Alpenstrasse 20 3052 Zollikofen Switzerland T 811 065 en
SecuriFire 500
Mounting and Installation
Technical Description

Table of Contents

Other manuals for Securiton SecuriFire 500

Questions and Answers:

Securiton SecuriFire 500 Specifications

General IconGeneral
TypeFire alarm control panel
Number of devices per loopUp to 250
DisplayGraphical LCD
Loops1 to 4
Detectors per loopUp to 250
Power Supply230 VAC / 115 VAC (depending on model)
NetworkingEthernet
Relative HumidityUp to 95% (non-condensing)
Enclosure Protection RatingIP30 (standard), higher ratings available with specific enclosures

Summary

Imprint and Document Information

Document Information and Notices

Document validity, revision status, and user feedback guidelines.

Safety Information

Safety Symbols and Precautions

Explains safety symbols, precautions, and environmental disposal.

Document History

System Overview

Key System Features

Highlights important functionalities, capabilities, and design aspects.

System Protection and Software

Details on overvoltage protection, earthing concepts, and software operation.

Technical Specifications and System Limits

Comprehensive technical data, system limits, and loop specifications.

Housing Design and Mounting

Control Unit Housing and Components

Overview of the integrated control map, housing parts, and connection points.

Control Map Mounting and Drilling Plan

Instructions for mounting the integrated control map and drilling plan details.

Interfaces and Connections

B7-CPB11 Main Control Unit

Description of the main control unit, its interfaces, and technical data.

Power Supply

Details on mains connection, power supply, and technical data.

Battery and External Consumer Power

Connections for emergency power supply (batteries) and external consumers.

Relay Output Connections

Information on connecting relay outputs to the B7-CPB11 control unit.

Power Supply Connection Examples

Visual examples illustrating power supply connections for different loads.

Monitored Inputs and Outputs

Details on connecting monitored inputs/outputs and associated technical data.

Monitored Output and Input Wiring

Diagrams showing connections for monitored outputs and inputs to the unit.

EPI Bus for External Devices

EPI bus connection details and technical data for external panels.

SecuriLine eXtended Loop

Details on SecuriLine eXtended loop connection, limits, and compatibility.

SecuriLine Extended Module Connections

Wiring diagrams for connecting various SecuriLine eXtended modules.

Stub Lines and Detector Base Connections

Connection details for stub lines and USB 501 detector bases.

Manual Call Points and Input Module Wiring

Wiring for manual call points and the BX-AIM advanced input module.

BX-IM4 Input Module Connection Details

Connection diagrams and information for the BX-IM4 input module.

BX-12 Input Module Wiring and Function

Connection details and functional description of the BX-12 input module.

BX-IOM Input/Output Module Connection

Wiring for the BX-IOM module, including voltage monitoring.

BX-OI3 Output/Input Module Wiring

Connection diagrams for the BX-OI3 output/input module.

BX-O214 and BX-01 Module Wiring

Wiring for BX-O214 output/input and BX-01 output modules.

BX-REL4 and BX-RGW Module Wiring

Connection details for BX-REL4 relay and BX-RGW radio modules.

BX-SOL and BX-FOL Module Wiring

Wiring for BX-SOL loop siren and BX-FOL loop flashlight modules.

BX-ESL Module and Addressable Loop Cable

Connection for BX-ESL module and recommended cable type for addressable loops.

Programming and Software

SecuriFire Studio Software Overview

Overview of SecuriFire Studio for system planning, commissioning, and diagnostics.

Planning

Loop Length and Power Planning

Calculating loop length, current consumption, and power requirements.

Battery Capacity and Charging Considerations

Ensuring adequate battery capacity and proper charging for power failures.

Battery Current Measurement

Commissioning

Program Loading and Loop Setup

Steps for initial program loading and SecuriLine addressable loop commissioning.

Fault Displays and Troubleshooting

Information on fault patterns, general troubleshooting, and specific fault causes.