Magnalock
®
Models M32, M62, and M82B
Installation and Operating Instructions
10027 S. 51st St. Ste 102
Phoenix, AZ 85044
Tel: 1-800-624-5625
Mon-Fri: 6:00am - 4:00pm PDT
securitron.com
techsupport@securitron.com

Questions and Answers

  • J
    Julie LeeAug 3, 2025
    Why is my Securitron lock's holding force reduced?
    • J
      James WaltonAug 4, 2025
      If you notice a reduced holding force in your Securitron lock, verify that the DC power source is Full-Wave Rectified (Half-wave Rectifier or AC Power is unacceptable). Also, check for the specified voltage and current draw at the Magnalock. Furthermore, ensure the strike mounting is properly installed. Finally, inspect the Magnalock and strike for any obstructions and confirm that the contact surfaces are clean.
  • D
    donnamillerAug 11, 2025
    What to do if my Securitron BondSTAT lock does not report secure?
    • R
      rogersmarkAug 11, 2025
      If the BondSTAT on your Securitron lock isn't reporting a secure status, begin by checking for the specified voltage and current draw at the Magnalock. Next, ensure the strike mounting is aligned correctly and pivots properly for closure to the Magnalock. Lastly, inspect the Magnalock and strike for any obstructions and ensure the contact surfaces are clean.
  • N
    Nicholas PopeAug 18, 2025
    What to do if my Securitron Magnalock does not release?
    • A
      alecalexanderAug 18, 2025
      If your Securitron Magnalock fails to release, first ensure that no voltage is present at the Magnalock and that it is not drawing current. Check if the strike is sticky or hard to release. Also, inspect the Magnalock and strike for obstructions, and ensure that the contact surfaces are properly cleaned.
  • M
    Michelle Jones DVMAug 27, 2025
    What to do if DPS does not report door status on Securitron Locks?
    • P
      Patrick HobbsAug 27, 2025
      If the DPS on your Securitron lock isn't reporting the door status, check the strike mounting for proper alignment and ensure proper door closure. Also, check for proper voltage/current on the switch and the resettable protection device.

Summary

Introduction

Specifications

General

Perform a Product Inventory

Checks for included components and hardware upon unpacking the product.

Have the Recommended Tools

Lists all essential tools required for the successful installation of the Magnalock.

Perform a Pre-Installation Survey

Assesses mounting area strength, wiring protection, and potential safety hazards prior to installation.

Installing a Magnalock

Attach the Template and Mark the Drill Holes

Guides template attachment and marking drill locations on door and frame for the lock assembly.

Drill the Holes for the Lock Body and Strike Plate

Install the Blind Nuts

Install the Strike Plate

Install the Magnalock

Magnalock and Strike Plate Alignment

Crucial alignment of Magnalock and strike plate for optimal BondSTAT and DPS function.

Magnalock Wiring

Wire Double Door Status

Wire Double Door Status-DPS

Describes wiring two DPS units in series for double door status reporting.

Wire for Emergency Release

Maintaining a Magnalock

Perform an Inspection

Checks rubber washers, debris, and rust on Magnalock and strike plate.

Clean the Magnalock

Specifies cleaning intervals and methods for Magnalocks.

Troubleshooting a Magnalock

Determining Wire Gauge

Warranty

Securitron Magnalock M32 Specifications

General IconGeneral
TypeElectromagnetic Lock
Voltage12/24 VDC
Duty CycleContinuous
Current Draw500mA @ 12V / 250mA @ 24V
FinishAluminum
MountingSurface
Holding Force1, 200 lbs (545 kg)
Operating Temperature-40°F to 150°F (-40°C to 65°C)