INSTALLATION MANUAL
CW3 Microcore Indirect Evaporative Cooler
Original English Instructions

Table of Contents

Questions and Answers

  • A
    Adam EverettAug 16, 2025
    What to do if the fan on my SEELEY INTERNATIONAL Climate Wizard CW3 Accessories won't start?
    • S
      savannahreyesAug 17, 2025
      If the fan on your SEELEY INTERNATIONAL Accessories unit fails to start, there are several potential reasons. First, check if the main power circuit breaker has tripped and, if so, reset it after identifying the cause of the overload. A burned-out fan motor will also prevent the fan from starting, necessitating a replacement. Low system voltage can be another culprit, requiring consultation with your power supply authority. Also, check the fault condition via the tri-colour LED on the cooler electronics module and rectify the fault as indicated, then restart the cooler. Finally, a controller failure could be the issue, which would require replacing the controller.
  • J
    Jason CarterAug 21, 2025
    How to fix a noisy SEELEY INTERNATIONAL Climate Wizard CW3 cooler?
    • R
      Robert RhodesAug 21, 2025
      A noisy SEELEY INTERNATIONAL Accessories cooler can be caused by fans that are out of balance due to dirt or other debris; cleaning the fans may resolve this. Alternatively, excessive back pressure from tight duct bends or undersized grilles could be the issue. In this case, re-evaluate the design, improve the duct layout, or change the grille sizes.
  • K
    Kelly MarshallAug 25, 2025
    What to do if my SEELEY INTERNATIONAL Accessories pump runs but there is no water circulation?
    • C
      Cynthia JohnstonAug 25, 2025
      If the pump in your SEELEY INTERNATIONAL Accessories unit runs but there's no water circulation or the cores lack water, several issues could be responsible. Insufficient water in the tank may be the problem; clean the water probe immersion prongs or replace the water probe. Blocked water hoses or spreaders can also prevent water circulation, so check and clean out any blockages. A blocked pump strainer can restrict water flow, so clean the pump strainer. Also, insufficient water supply pressure can be a factor; check and confirm the water supply pressure. Finally, if the water solenoid is installed incorrectly, it can impede water flow; ensure it is installed in the correct water flow direction.
  • R
    Ryan MartinezAug 28, 2025
    How do I get rid of a bad smell from my SEELEY INTERNATIONAL Climate Wizard CW3 Accessories unit?
    • S
      samantha71Aug 28, 2025
      An unpleasant odor from your SEELEY INTERNATIONAL Accessories unit can arise from several sources. If the cooler cores are new, fill the tank, run the pump briefly to wash the pads, drain the tank, refill, and repeat several times if the odor persists; it should dissipate after some hours of operation. The cooler's location near a source of unpleasant odor can also be the cause; remove the odor source or relocate the cooler. Algae in the tank water can produce odors; drain the pan, clean it thoroughly with a strong cleansing agent, refill, and change the cores. If the cores remain wet after shutdown, run the fan on "vent" for 10 minutes after the cooling cycle to dry them out. Finally, heavy core deposits can cause odors; clean or replace the cores.
  • M
    Maria BriggsAug 31, 2025
    Why is my SEELEY INTERNATIONAL Accessories constantly overflowing?
    • E
      erik30Aug 31, 2025
      Continuous overflow of water in your SEELEY INTERNATIONAL Accessories unit can be caused by heavy core deposits, which can be resolved by cleaning or replacing the cores. Another potential cause is a drain valve failure, requiring replacement of the drain valve. Also, check that the water solenoid is installed correctly, ensuring it's in the correct water flow direction.
  • R
    Robert SuttonSep 5, 2025
    Why is water coming out of the outlet of my SEELEY INTERNATIONAL Climate Wizard CW3?
    • R
      Ryan ClaytonSep 5, 2025
      Water entering the cooler outlet of your SEELEY INTERNATIONAL Accessories unit can be due to loose water hose connections; tighten them. A broken water hose can also cause this issue; replace any cracked or broken hoses. If the cores are not fitted correctly into the pad frames, install the pad frame correctly. Incorrect or damaged cores can also lead to water leakage; replace them with new Microcore pads.
  • S
    Sara BakerSep 8, 2025
    Why won't the pump on my SEELEY INTERNATIONAL Climate Wizard CW3 start?
    • J
      josephchurchSep 8, 2025
      If the pump on your SEELEY INTERNATIONAL Accessories fails to operate, it could be due to a tripped circuit breaker. Check the pump for faults and replace it if necessary. Alternatively, the pump motor may have failed, requiring pump replacement.
  • J
    Joseph SmithNov 12, 2025
    Why is my SEELEY INTERNATIONAL Climate Wizard CW3 Accessories unit not cooling enough?
    • T
      terry96Nov 12, 2025
      Inadequate cooling in your SEELEY INTERNATIONAL Accessories unit can stem from several causes. Undersized ducts may be the problem, requiring a cooling load design to determine the correct unit, ducting, and outlet sizes. Clogged or dirty cooling cores will also reduce cooling efficiency, so they should be cleaned or replaced. Also, dry cores or a lack of water during operation can be a factor; inspect the water distribution system for obstructions in hoses and check the pump. If you notice dry patches in the cores, check for blockages inside the pump hoses and in the spreaders feeding the core assemblies. Insufficient air discharge openings or inadequate exhaust from the building can lead to high humidity and discomfort, so ensure adequate exhaust by opening windows and doors. Finally, ex...