(English)
INSTALLATION MANUAL
EXVQ Evaporative Coolers
ILL1672-A
Original English Instructions

Questions and Answers

  • R
    richardarmstrongAug 17, 2025
    What to do if the fan on my Seeley Air Cleaner fails to start?
    • G
      Gary RodgersAug 17, 2025
      If the fan on your Seeley Air Cleaner isn't starting, the main power circuit breaker might have tripped; check for the cause of the overload and reset the breaker. The fan motor could also be burned out, necessitating a replacement. A broken belt will also prevent the fan from starting, so replace the belt if it's broken. Check if the belt or pulley is loose and tighten them. Low system voltage can also cause this issue, so consult with your power supply authority. Lastly, a MagIQtouch Controller failure could be the cause, requiring you to replace the MagIQtouch Controller.
  • C
    Courtney RogersAug 20, 2025
    How to fix a noisy Seeley BREEZAIR EXVQ Air Cleaner?
    • H
      Heather SmithAug 20, 2025
      A noisy Seeley Air Cleaner could be due to a fan being out of balance because of dirt; clean the fan. Also, too much back pressure can cause noise; re-evaluate the design, improve the duct layout, or change the grille sizes.
  • T
    Traci SmithAug 25, 2025
    What to do if the pump on my Seeley BREEZAIR EXVQ Air Cleaner fails to operate?
    • J
      Juan ReidAug 25, 2025
      If the pump in your Seeley Air Cleaner fails to operate, first check if the circuit breaker has tripped. If so, check the pump for faults and replace it if necessary. Alternatively, the pump motor itself may have failed, requiring a pump replacement.
  • C
    cynthia32Aug 27, 2025
    How to get rid of the unpleasant odor from my Seeley BREEZAIR EXVQ Air Cleaner?
    • C
      Chris SnyderAug 27, 2025
      An unpleasant odor from your Seeley Air Cleaner can stem from several causes. New cooler pads may initially produce an odor; fill the pan, run the pump briefly to wash the pads, drain the pan, and repeat as needed until the odor lessens, which should dissipate with operation. The cooler might be near an odor source, so remove the source or relocate the cooler. Algae in the pan water can also cause a smell; drain the pan, clean it thoroughly with a strong cleansing agent, refill it, and change the pads. If the pads remain wet after shutdown, run the fan on 'vent' for 10 minutes after the cooling cycle to dry them. Heavy pad deposits can also lead to odors, so clean or replace the pads.
  • T
    Trevor OrtizAug 30, 2025
    Why is my Seeley Air Cleaner pump running but there is no water circulation?
    • V
      valerie37Aug 30, 2025
      If the pump in your Seeley Air Cleaner runs but there's no water circulation, or the pads lack water, start by adjusting the float level. Check for and clear any blockages in the water hoses. Also, inspect and clean the pump strainer. Ensure there's sufficient water supply pressure. Finally, verify that the water solenoid is installed with the correct water flow direction.
  • C
    Chris ChristensenSep 2, 2025
    What causes continuous overflow of water in Seeley BREEZAIR EXVQ?
    • A
      Aaron MeltonSep 2, 2025
      Continuous overflow of water in your Seeley Air Cleaner may be due to an incorrect float valve adjustment; adjust the float valve. Heavy pad deposits can also cause overflow, so clean or replace the pads. A drain valve failure can also be the culprit, requiring a replacement of the drain valve. Ensure the water solenoid is installed in the correct water flow direction.
  • J
    Joshua WarrenSep 6, 2025
    Why is water entering the cooler outlet of my Seeley BREEZAIR EXVQ Air Cleaner?
    • K
      Kyle CantuSep 6, 2025
      If water is entering the cooler outlet of your Seeley Air Cleaner, check for loose water hose connections and tighten them. Replace any cracked or broken hoses. Ensure the cover is fitted on the float valve, replacing the float valve if necessary. Verify that the pads are correctly fitted into the pad frames and install the pad frame correctly. If the pads are incorrect or damaged, replace them with new Chillcell pads.
  • L
    Linda DawsonSep 9, 2025
    What to do if the air sensor on my Seeley BREEZAIR EXVQ Air Cleaner is not working?
    • J
      John SolomonSep 9, 2025
      If the optional Air Sensor on your Seeley Air Cleaner isn't working, first ensure the Air Sensor is properly plugged into the control box. If it is, the Air Sensor itself may have failed and require replacement.
  • Q
    qmendezNov 13, 2025
    Why is my Seeley Air Cleaner not cooling enough?
    • M
      Michael AnthonyNov 13, 2025
      If your Seeley Air Cleaner isn't cooling adequately, several factors could be the cause. It might be due to an under-sized cooler, requiring a replacement with a larger one. Alternatively, the ducts may be too small; conduct a cooling load design to determine the correct size for the unit, ducting, and outlets. Clogged or dirty cooling pads can also reduce efficiency, so clean or replace them. Ensure the pads aren't dry and the water distribution system isn't obstructed, checking the hoses and pump. Insufficient air discharge openings or inadequate exhaust can lead to high humidity, so ensure adequate ventilation by opening windows and doors. In cases of excessive ambient humidity, there's no remedy other than to shut off the pump. Lastly, check for a slipping belt, tightening it by readju...

Summary

Important Safety Instructions

Warnings and Responsibilities

Key safety warnings, employer/employee duties, and risk assessment.

Site Considerations and Requirements

Points to consider for safe working and other essential requirements.

Quick Guide

Safety and Site Preparation

Read safety, select cooler location, and prepare the site.

Core Installation Procedures

Install roof jack, power, controller, and adjust motor/belt.

Testing and Settings Configuration

Refit pads, test pump, and configure cooler operating settings.

Finalizing the Installation

Complete final checks, clean up, and provide customer handover.

Installation

Cooler Location and Mounting

Site selection, access, mounting procedures, and leg support.

Electrical and Water Connections

Wiring, power supply, controller, and water system setup.

Motor, Belt, and Settings Adjustments

Setting motor amperage, belt tension, and low speed.

Commissioning

Initial Tests and Diagnostics

Test operation, check LEDs, controller info, and salinity status.

Fault Diagnosis and Water Level Setup

Understand fault codes and correctly set the water level.

System Checks and Adjustments

Test drain valve, pump, refit pads, and adjust settings.

Final Verification and Handover

Completion checklist, customer handover, clean-up, and final test.

Trouble Shooting