    Sandy GarciaAug 15, 2025
    What to do if Seeley Accessories provides inadequate cooling?
    • T
      Tyler DuncanAug 15, 2025
      If your Seeley Accessories cooler isn't cooling adequately, start by checking that the water supply is turned on and that water is flowing to the pads. For LPQI models, inspect the water distribution channels under the lid for blockages; remove any debris and ensure the rubber channel cover is properly refitted. Also, make sure there are enough exhaust openings for the conditioned air. Keep in mind that on days with high ambient humidity, the cooler's ability to lower the temperature will be reduced.
  • N
    Nicole HudsonAug 18, 2025
    How to get rid of unpleasant odour from Seeley Accessories?
    • D
      Douglas WagnerAug 18, 2025
      If your Seeley Accessories cooler is emitting an unpleasant odour, it may be due to new pads. Use the 'Pad Flush' function in the SETTINGS menu of your MagIQtouch Controller to flush the pads. Fill the tank, run the pump briefly to wash the pads, drain the tank, and refill. Repeat this process several times if the odour persists. The odour should dissipate after a few hours of operation.
  • L
    larry80Aug 21, 2025
    What to do if my Seeley Air Cleaner is not cooling properly?
    • T
      Troy HawkinsAug 21, 2025
      If your Seeley Air Cleaner isn't cooling well, several factors could be the cause. It might be due to an under-sized cooler, in which case you should replace it with a larger one. The ducts could be too small; a cooling load design can help determine the correct unit, ducting, and outlet sizes. Check for clogged or dirty cooling pads and clean or replace them as needed. Also, ensure the pads aren't dry due to obstructions in the water distribution system or a faulty pump. Insufficient air discharge openings or inadequate exhaust can cause high humidity; make sure you have enough open windows and doors for stale air to escape. Finally, excessive ambient humidity can also reduce cooling effectiveness; on very humid days, shutting off the pump may be the only option.
  • C
    Crystal GarrettAug 25, 2025
    Why is my Seeley Air Cleaner fan not starting?
    • T
      Taylor FernandezAug 25, 2025
      If the fan on your Seeley Air Cleaner isn't starting, there are several possible reasons. The main power circuit breaker may have tripped; check for an overload and reset the breaker. The fan motor might be burned out, requiring replacement. Low system voltage could also be the issue, so consult with your power supply authority. Check the tri-colour LED on the cooler electronics module for fault indications and rectify the fault accordingly, then restart the cooler. Lastly, the controller itself might have failed and need replacing.
  • M
    Matthew SmithAug 27, 2025
    Why is my Seeley Air Cleaner so noisy?
    • A
      Amber CarterAug 27, 2025
      A noisy Seeley Air Cleaner could be due to a couple of reasons. The fan might be out of balance because of dirt or debris; try cleaning the fan. Alternatively, there could be too much back pressure. In that case, re-evaluate the design, improve the duct layout, or change the grille sizes.
  • T
    Tara CamposAug 30, 2025
    What to do if my Seeley Air Cleaner pump fails to operate?
    • M
      Megan EnglishAug 30, 2025
      If the pump in your Seeley Air Cleaner isn't working, it could be due to a tripped circuit breaker. Check the pump for faults and replace it if necessary. Another possibility is pump motor failure, which would also require replacing the pump.
  • R
    Richard JonesSep 2, 2025
    What to do if my Seeley Air Cleaner pump runs but no water circulates?
    • S
      Steven PalmerSep 2, 2025
      If the pump in your Seeley Air Cleaner is running but no water is circulating, check these potential issues. Ensure there's sufficient water in the tank by adjusting the float level. Inspect the water hoses for blockages and clean them out if necessary. Also, check the pump strainer for blockages and clean it. Confirm that the water supply pressure is adequate. Finally, verify that the water solenoid is installed in the correct water flow direction.
  • S
    sandrabyrdSep 5, 2025
    How to fix continuous water overflow in my Seeley Air Cleaner?
    • C
      Carlos JarvisSep 5, 2025
      If your Seeley Air Cleaner is continuously overflowing, it might be due to several reasons. The float valve adjustment may not be correct; adjust the float valve. Heavy pad deposits can also cause overflow, so clean or replace the pads. A drain valve failure could be the culprit, requiring you to replace the drain valve. Lastly, check if the water solenoid is installed correctly, ensuring it's in the correct water flow direction.
  • Z
    zhornSep 8, 2025
    Why is water entering the outlet of my Seeley Air Cleaner?
    • K
      Katie McgeeSep 8, 2025
      If water is entering the outlet of your Seeley Air Cleaner, check the following: 1. Tighten any loose water hose connections. 2. Replace any cracked or broken water hoses. 3. Replace the float valve if the cover is not fitted. 4. Ensure the pads are fitted correctly into the pad frames and install correctly if needed. 5. Replace incorrect or damaged pads with new Chillcel pads.
  • M
    Megan WhiteSep 12, 2025
    How to get rid of the bad smell from my Seeley Air Cleaner?
    • M
      Mrs. Patricia HenrySep 12, 2025
      If your Seeley Air Cleaner has an unpleasant odour, it could be due to a few reasons. New cooler pads can sometimes cause this; fill the tank, run the pump briefly to wash the pads, drain the tank, and repeat several times. The odour should dissipate after a few hours of operation. The cooler might be located near a source of unpleasant odours; remove the source or relocate the cooler. Algae in the tank water can also cause odours; drain the pan, clean it thoroughly with a strong cleansing agent, refill it, and change the pads. If the pads remain wet after shutdown, run the fan on 'vent' for 10 minutes after the cooling cycle to dry them out. Heavy pad deposits can also contribute to the smell, so clean or replace the pads.

Summary

Safety Instructions

General Safety Warnings

Critical warnings regarding fire, electric shock, and injury, emphasizing proper usage and maintenance.

Operational & Warranty Guidance

Maintenance for Warranty Validity

Emphasizes that regular, documented maintenance by a qualified technician is mandatory for warranty coverage.

Advanced MagIQcool Operations

Error Handling and Water Management

Maintenance Essentials

Residential Maintenance Schedule

2-Year Component Checks

Detailed checks for all cooler components to be performed every two years for residential use.

Residential Maintenance Records

Bleed System Maintenance Requirements

Commercial Maintenance Schedule

3-Month;Twice-Yearly Checks

Maintenance schedule for commercial/industrial units, requiring checks every three months or twice annually.

High Operation Hour Maintenance

Troubleshooting Common Issues

Odor, Cooling, and Power Issues

Solutions for common problems like unpleasant odors from new pads, inadequate cooling, and the cooler turning on/off unexpectedly.

Product Warranty Registration (Australia)

Warranty Terms and Information (Australia)

General Warranty Conditions

Details the warranty period, coverage, exclusions, and consumer law rights for evaporative coolers.

Warranty Claim and Procedure (Australia)

Seeley LCQ Specifications

General IconGeneral
BrandSeeley
ModelLCQ
CategoryFreezer
LanguageEnglish

Related product manuals