Section 7: Repair Assessment Guide
Bambi Bucket Service Manual – Models 6072-1821 25
Cables Repair Criteria
Category 1: Safety
Cease operations and repair immediately.
• One or more broken suspension cables or end fittings.
• Broken deployment cable.
Category 2: Operational
Repair before next day’s operation or eight hours flight time.
If three or more individual suspension cables or the deployment cable have the following defects:
• 10 or more randomly distributed broken strands or four adjacent broken strands
• Visible kink(s).
• Separation of the strands due to twisting (known as “bird-caging”).
• Evidence of heat damage.
• Abrasion wear comprising of more than 1/3 of the original diameter of the outside individual
strands.
• Any visible reduction in outside diameter due to overload.
• Cracked or broken end fittings (some elongation of cable eyes is acceptable).
Category 3: Monitor
Monitor and/or repair if condition deteriorates.
• Wear, broken strands, kinks and twisting in cable that does not exceed the limits defined in
Category 2 defects.