Section 8: Repairs
Bambi Bucket Service Manual – Models 6072-1821 45
Valve Repair and Replacement
Dump Valve Replacement
Replacement dump valve assemblies come complete with new purse strings, bolts, nuts, washers and
gasket.
To replace a valve:
1. Remove the old valve, gasket and all butyl tape.
2. Stand the bucket up with the valve hole on the
bottom.
3. Place the new gasket in with the holes aligned to the
grommets on the shell.
4. Place the stainless washers and then the rubber washers onto the bolts. Insert the bolts up
from outside of shell.
5. Place the new valve into the bucket where the vertical
seam on the valve is in-line with either of the IDS
restrainer cable brackets on the shell.
6. Install the remaining stainless washers and nuts onto
the bolts and fasten them until two threads on the
bolts show. Do not over-tighten.