Do you have a question about the Seiko KINETIC AUTO RELAY 5J21 and is the answer not in the manual?
frequency of crystal oscillator | 32, 768 Hz |
---|---|
loss/gain | Less than 15 seconds at normal temperature range (5° C ~ 35° C) (41° F ~ 95° F) |
operational temperature range | –10° C ~ +60° C (14° F ~ 140° F) |
display system | Hour, minute and second hands |
---|---|
driving system | Step motor, 2 pieces |
IC (Integrated Circuit) | C-MOS-IC, 2 pieces |
duration of charge | Approximately 4 years (Full charge) |
---|---|
generating system | Miniature AC generator |
kinetic electricity storage unit | Button type, 1 piece |
Automatic stopping of watch hands to conserve stored electric energy after 3 days of inactivity.
Allows watch hands to quickly indicate current time using stored energy after being awakened from power save mode.
Allows manual activation of the power save mode to conserve energy for long periods of disuse.
Details the procedure for awakening the watch and synchronizing hands using the time relay function.
Provides notes on swinging the watch, sounds during operation, and initial time setting after purchase.
Explains manual charging steps when the second hand moves at two-second intervals, indicating low power.
Guidance on estimating power reserve based on wearing habits and using the manual power save function.
Warns against using the crown to stop hands for saving energy, advising manual power save instead.