Details the primary functions of the control panel buttons for programming, operation, and navigation.
Explains the meaning of the green LED for dosage and the red LED for alarm situations.
Lists and describes the terminal connections for alarm relay, I/O, sensor inputs, and level control.
Instructions on how to access the programming menu using the PROG key.
Overview of the main menu structure and key configuration parameters available.
Details the parameters adjustable within the Setting Menu, such as flow rate and language.
Explains how to select measurement functions like pH or Redox measurement.
Describes how to change the pump's display language using the control panel.
Details how the pump operates in constant mode and how to manually adjust flow rate.
Configuring the target pH value and setpoint type (acid/alkaline).
Setting the proportional band and alarm band for pH control.
Setting the Over Feed Alarm time and measurement resolution.
Procedures for probe calibration and manual temperature input.
Configuring the target Redox value and setpoint type (high/low).
Setting the proportional band and alarm band for Redox control.
Setting Over Feed Alarm time and probe calibration for Redox measurements.
Setting the pump's maximum flow rate and the display unit for flow.
Setting the alarm relay to be open (default) or closed during alarm situations.
Manually calibrating flow by entering the cc/stroke value.
Performing automatic flow calibration using pump strokes and measured volume.
Accessing statistics like operation time, strokes, quantity dosed, and power.
How to reset the pump operation counters for statistics.
Setting, using, and eliminating the password for menu access and modification.
Activating the flow sensor and configuring the number of signals for alarm triggers.
Configuring whether to stop dosage or just signal an alarm when the level sensor is activated.
Selecting the display unit for flow measurement (L/h, Gph, ml/m, or %).
Step-by-step guide for performing automatic pH calibration.
Guide for manual pH calibration, including user-inputted values.
Step-by-step guide for performing automatic Redox calibration.
Guide for manual Redox calibration, including user-inputted values.
Details on Level alarm display, cause, and interruption to pump operation.
Details on Memory alarm display, cause, and interruption from external impulses.
Details on Flow alarm display, cause, and interruption due to sensor signals.
Troubleshooting for parameter errors and O.F.A. alarms.
Troubleshooting for measurement outside band and probe not calibrated alarms.