TEC Series v 3.2X
Page 32
4.2.1.2 FIND NAME
To select the find name function, press "2" from the Codes/Names
menu. You will be prompted for 1 - 6 characters. Select
characters in the same manner that you programmed names into
memory (See the diagram on Pg. 31). When you have entered all
desired characters, press "#", then "*".
1-6 CHAR. <CR>
CODE =
XXX<CR>MORE
NO MATCH
<CR> TO CONT
SHOW ALL CODES
Select this sub-menu from the Codes/Names menu by pressing "8". This selection will list
code numbers and all data associated with code numbers, sorted by CODE NUMBER in ascending
order. It sends this data out the optional serial port (OPTKPRT) to a printer or terminal.
SHOW ALL NAMES
Select this sub-menu from the Codes/Names menu by pressing "9". This selection will list code
numbers and all data associated with code numbers, sorted by NAMES in ascending order. It sends
this data out the optional serial port (OPTKPRT) to a printer or terminal.
ENABLE ACCESS GROUPS
(Following settings available with optional CLOCK [OPTCLK])
Access Groups allow more control of a TEC by adding time zone
control and increased card reader control.
To enable Access Groups from the factory default of 0,
press "8" from the Codes / Names menu to get this sub-menu.
Press "1" to enable Access Groups, and press "*". This will
return you to the Codes / Names menu.
ENA ACC GRP = 0
ENTRY CONTROL
The Entry Control menu comes with factory defaults that
should be sufficient for most installations. These default values
are shown on Pg. 28 and 29 Some functions work with options
that may not be present on your TEC unit. To get the menu at
right, press "2" and then select the entrance to modify,The TEC
unit can support up to 4 entrances with options installed.
ENTRANCE X UNLOCK TIME
Press "1" from the Entry Control menu to set the time in seconds
from 1 to 99 seconds. This is the length of time the door control
relay for door 1 will be energized. The factory default is 10
seconds. A good rule of thumb for entry time is 3 seconds plus 2
seconds for every step from the TEC to the entrance being
controlled. To change time, key in the time desired and press the
"*" key. You will be returned to the Entry Control menu.
ENT X CONFIG
SEL FUNCT 1 - 4
SEL ENT _
ENT X
UNLOCK TIME = 10
This message will display whatever code number matches
the letters selected. If there is more than one name with similar
letters, pressing the "*" key will display additional code numbers
that meet the selection criteria.
If there is no match, you will be prompted to press either the
ā*ā from the keypad, or Enter key from the terminal. A "*" will return
to sub-menu 1.
SETUP AND PROGRAMMING