TB-6123 Revision 10/06
Page 4 of 12
7. Port expand should be set to yes (factory default).
8. Press Enter button once more to cycle to next setting before hitting Menu button to exit.
Note: Setting will not change if you don’t cycle to the next setting (by hitting the Enter
button).
B. Terminator Jumper, RS-485 Switch, RS-232 Switch and Relay Terminal
1. Terminator Jumper needs to be jumper only if clocks are in a daisy-chain. Jumper the
first SmartlogX
3
™ and the last SmartlogX
3
™ on the daisy-chain only. Stand alone
SmartlogX
3
™ does not need to be jumper.
2. RS-485 comes default on SLAVE position (right side) and does not need to be switched
unless unit is on a daisy-chain. For units on a daisy-chain set RS-485 to MASTER (left
position) for the first SmartlogX
3
™ (master clock) only.
3. Relay Terminal, The relay connections can be made on the back of the SmartLogX
3
(refer to figure 1) and can be used to control doors, gates, etc. The relay can hold a max
of 5A 250VAC/30VDC and 10A125VAC.
B. Cable Connections
Refer to Figure 2
1. IMPORTANT PC to First SmartlogX
3
™ Data Connection: Be sure to use the cable
provided inside box with unit. Connect the cable from the right port (RS-232) of the
SmartlogX
3
to the DB9 serial adapter connected to an open serial port on the PC
used. Cable is non-inverted and flat type when laid across table top if user desires to
make his/her own cable. Make sure cable is no longer than 50ft from the PC to the first
SmartlogX
3
™.
2. SmartlogX
3
™ to SmartlogX
3
™ Data Connection: These cables are different from the
cable supplied in the box with the SmartlogX
3
™. These cables are inverted and are the
same type of cables used in wiring of home telephones. Connect these cable to the left
port (RS-485) of first Smartlogto the left port (RS-485) of the second SmartlogX
3
only.
Note: No other clocks except the first clock (master clock) will use the right port (RS-
232), all other will connect through the left port (RS-485) in parallel, a RJ11 splitter will
be needed for daisy-chaining more than two units.
C. Mounting the SmartLogX
3
And Scanner (Optional)
1. Mount SmartlogX
3
at convenient location, makes sure to mount the SmartLogX
3
™ at a
height above the floor where all operators can see the display of the SmartlogpX
3
™ and
perform the necessary tests. Mount the barcode scanner to where all users are able to
reach the scanner. Use the anchor and screws provided with the SmartlogX
3
™.