OHMS
ADJ:
The
OHMS
ADJ
is
the
same
as
that
found
оп
most
meters.
Prior
to
measuring
resistance,
the
FE149
leads
are
shorted
together
and
the
OHMS
ADJ
is
rotated
for
a
full
scale
deflection(zero
ohms)
as
readon
the
ohms
scale
of
the
meter.
FUNCTION
SWITCH:
The
FUNCTION
SWITCH
is
a
push
button
switch
used
to
select
the
desired
function
for
the
measurements
to
be
performed
by
the
FE149.
Simply
push
inthe
desiredfunction,
plusor
minus
DC
volts,
AC
volts,
Ohms,
BATT
check,
plus
or
minus
DC
current
or
AC
current,
a
total
of
8
functions.
RANGE
SWITCH:
The
RANGE
SWITCH
is
a
push
button
switch
to
select
the
desired
range
ofcurrent,
voltage
or
resistance
to
be
measured
with
the
FE149.
There
are
a
total
of
8
different
ranges
available
on
the
FE149.
OPERATING
THE
ЕЕ149
Тһе
Sencore
FE149
Senior
Field
Effect
Meter
is
extremely
easyto
operate.
Simply
depress
the
desired
function
button
on
the
FUNCTION
switch
and
depress
the
de-
sired
range
button
on
the
RANGE
switch,
connect
theleads,
and
read
the
results
on
meter.
Here
is
a
brief
description
of
how
each
test
is
performed
with
the
FE149.
ADING
DC
VOLTS:
To
read
DC
volts
on
the
FE149,
depress
either
the
minus
DC
or
plus
DC
button
on
the
FUNCTION
switch.
Depress
the
desired
range
button
for
the
voltage
to
be
measured
from
.5
volts
to
1500
volts
on
the
RANGE
switch.
If
the
voltage
to
be
measured
is
unknown,
start
with
one
of
the
higher
ranges
to
see
how
much
voltage
is
present
and
depress
the
range
button
that
will
give
the
desired
meter
deflection.
When
measuring
DC
voltages
in
RF-IF
circuits,
a
100K
resistor
at
the
endof
the
probe
lead
will
reduce
the
capacity
loading
effects
and
not
upset
the
circuits
for
the
most
accurate
readings.
The
DC
voltage
is
read
on
the
two
black
scales
just
above
the
mirror
on
the
meter.
The
top
DC
scale
is
from
zero
to
.
5
volts
and
each
mark
is
equal
to
.
01
volts.
Тһе
bottom
scale
is
zero
to
1.
5
volts
and
each
mark
is
equal
to
.
02
volts.
The
zero
to
5
scale
is
used
for
the
.
5,
5,
50,
and
500
volt
ranges
and
the
zero
to
1.5
scale
is
used
for
the
1.5,
15,
150,
and
1500
volt
ranges.
In
use,
the
meter
indication
is
multiplied
by
1,
10,
100,
or
1000
depending
upon
the
range.
For
example,
if
the
15
volt
RANGE
button
is
depressed
and
the
meter
reads
.
68
volts,
the
actual
voltage
is
.
68
times
10
or
6.8
volts
DC.
=рс
+рс/
0
ал
Е
ЕА
et oe
iig
i
oA]
L—
vorracse
—J
.5У
1.5V
5V
15V
50У
150У
500У
1500У
DC
RANGES
WITH
39421
HI
V
PROBE——SKV
15КУ
50KV
READING
DC
VOLTS
ZERO
CENTER
SCALE:
The
zero
center
scales
are
used
to
read
plus
or
minus
voltages
without
the
necessity
of
changing
polarity
with
the
leads
or
Function
switch.
То
use
the
zero
center
scales,
depress
the
plus
DC
voltage
function
button
and
adjust
the
ZERO
ADJ
control
until
the
meter
pointer
reads
at
the
ro
mark
inthe
center
of
the
scale.
This
isthe scale
directly
below
the
mirror
оп
3
meter.
This
gives
ranges
of
plus
or
minus
zero
to
.
25
volts
(top
scale)
and
plus
minus
zero
to
.75
volts
(bottom
scale),
times
10,
100,
or
1000
depending
upon
the
range
button
that
is
depressed.
If
the
meter
swings
up
scale
or
to
the
right,
it
is
a
positive
voltage.
If
the
meter
swings
down
scale
or
to
the
left
it
is
a
negative
voltage.
This
unique
feature
allows
you
to
determine
the
polarity
as
well
as
the
amplitude
of
a
DC
voltage
and
is
very
handy
in
solid
state
work.
5