EasyManua.ls Logo

Sencore CB42 User Manual

Sencore CB42
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
CB42
AUTOMATIC
CB
ANALYZER
OPERATION,
APPLICATION
AND
MAINTENANCE
MANUAL
{"i~Z'
SENCORE
~
THE ALL AMERICAN LINE OF HIGH QOALITY TEST EOUIPMENT
Question and Answer IconNeed help?

Do you have a question about the Sencore CB42 and is the answer not in the manual?

Sencore CB42 Specifications

General IconGeneral
BrandSencore
ModelCB42
CategoryMeasuring Instruments
LanguageEnglish

Summary

Description

Introduction

Overview of the CB42 analyzer and its purpose in CB service.

Features

Highlights key capabilities for CB alignment and troubleshooting.

Specifications

Details technical specifications for RF generator, frequency counter, and other parameters.

Controls

Digital Readout Selector and Functions

Selector for various digital readout functions like RF Power, Modulation, and Off Channel.

RF-IF Generator and Audio Controls

Controls for signal generation, including AM/SSB modulation and audio frequency selection.

Output and Input Jacks

Connectors for signals, including Microvolt Output, Speaker Sub, and general inputs/outputs.

Operation

Power Connections

Instructions for connecting the CB42 to AC or DC power sources.

Transceiver Set-Up

Guidance on connecting and configuring the transceiver for testing.

RF Generator

Details on using the RF signal generator for AM and SSB testing.

IF Generator

Procedure for using the adjustable IF generator for alignment.

Audio Output

Instructions for using the audio generator for modulation and audio tests.

Frequency Counter

How to use the frequency counter for measuring signal frequencies.

Percent Off Channel Test

Percent Off Channel Test Procedure

Steps to measure transmitter frequency deviation against FCC specifications.

Crystal Check

Crystal Check Function

Procedure for testing crystal activity and fundamental frequency.

RF Wattmeter

Instructions for measuring Peak Envelope Power (PEP) of RF signals.

Audio Watts and Speaker Sub

Audio Watts and Speaker Sub Usage

Method for measuring receiver audio output power and sensitivity.

Scope Adapter

Scope Adapter Function and Use

How to use the scope adapter output for modulation envelope analysis.

Applications

Transceiver Theory & Troubleshooting

Explains basic CB transceiver theory and troubleshooting techniques.

AM Transmitter

Block diagram and signal flow for AM transmitters.

AM Receiver

Block diagram and signal flow for AM receivers.

SSB Transmitter

Block diagram of a typical SSB transmitter.

SSB Receiver

Block diagram of a typical SSB receiver.

Frequency Synthesizer

Explanation of frequency synthesizer circuits for channel selection.

Phase Locked Loop

Description of Programmable Phase-Locked Loop (PPLL) circuits.

AM Receiver Tests

Audio Output Power

Method to measure receiver audio output power and identify common defects.

Squelch

Test procedure for determining AM receiver squelch operation.

EIA Sensitivity Test

Procedure to measure AM receiver sensitivity as per EIA standards.

Adjacent Channel Rejection

Test for AM receiver's selectivity against adjacent channel interference.

AGC

Procedure to test the AM receiver's Automatic Gain Control (AGC) circuit.

Receiver Gain

Method to determine AM receiver gain in dB.

EIA Impulse Noise Limiter Test

Test for AM receiver ANL/ANB circuit effectiveness using NL204.

SSB Receiver Tests

General SSB Receiver Test/Clarifier Adjustment

Initial check and adjustment of SSB receiver clarifier for proper operation.

SSB Sensitivity

Procedure to measure SSB receiver sensitivity using the (S+N)/N ratio.

SSB Adjacent Sideband Rejection

Test for SSB receiver's ability to reject unwanted sideband signals.

SSB AGC

Procedure to test SSB receiver AGC circuit performance.

SSB Receiver Squelch

Test for determining the SSB receiver squelch operation point.

SSB Impulse Noise Test

Test for SSB receiver ANL/ANB effectiveness using NL204.

AM & SSB Transmitter Tests

AM Transmitter Frequency

Procedure to measure AM transmitter frequency accuracy.

SSB Transmitter Frequency

Procedure to measure SSB transmitter frequency accuracy.

SSB Transmitter Percent Off Channel

Test to measure SSB transmitter frequency deviation.

SSB Transmitter Clarifier Control Test

Procedure to test SSB clarifier control for frequency stability.

Scope Adapter Applications

Specific applications of the scope adapter for waveform analysis.

Residual Carrier Noise Check

Residual Carrier Noise Check Procedure

Method to detect and analyze residual carrier noise in transmitter output.

SSB Applications

SSB One-Tone Method

Using a single tone to test SSB balanced modulator performance.

SSB Two-Tone Method

Using two tones to test SSB balanced modulator performance.

Maintenance and Service

Introduction

Overview of the Maintenance and Service section.

Functional Description and Block Diagram

Explanation of the CB42's functional blocks and overall system diagram.

Calibration Procedure

Instructions for performing essential calibration procedures.

Equipment Requirements

List of equipment necessary for calibration and testing.

Sencore Safety Reminders

Safety Reminders

Crucial safety precautions for operating and servicing electronic equipment.

Schematic and Parts List with "Signal Tracer" Coding

Index

Index of PC boards, schematic references, and component locations.

Key Symptom/Test Cross Check

AM Receiver

Cross-references common AM receiver customer complaints to diagnostic tests.

AM Transmitter

Cross-references common AM transmitter symptoms to diagnostic tests.

SSB Receiver

Cross-references common SSB receiver symptoms to diagnostic tests.

SSB Transmitter

Cross-references common SSB transmitter symptoms to diagnostic tests.

General Tests

RF Generator

Setup and application for using the RF generator for receiver testing.

IF Generator

Setup and application for using the IF generator for alignment.

Audio Generator

Setup and application for using the audio generator for modulation tests.

Frequency Counter (1 MEG)

Procedure for using the 1 MEG frequency counter input.

Crystal Check

Procedure for testing crystal activity and fundamental frequency.

Allowable Channel Carrier Frequencies

Allowable Channel Carrier Frequencies

Reference table for CB channel frequencies and FCC limits.

Using the dB Conversion Chart

Using the dB Conversion Chart

Guide on how to use the dB conversion chart for calculations.

Related product manuals