1. Install the batteries by pushing down
the locking tab and sliding the handle
away from the top of the instrument. When
replacing handle be sure the tab is securely
in place and replace the retaining screw.
2. IMPORTANT: CAREFULLY OBSERVE
POLARITY WHEN CHANGING BATTERIES.
Instrument will not function with improperly
installed batteries.
3. Slide the on/off switch to the right to turn on.
4. Allow unit to go through the warm up
sequence in clean air. The tick will sound
and the leak indication light will ash for a
few moments. This requires up to 60 seconds
to fully warm up.
5. Extend the goose neck (the sensor and
cap is at the tip).
6. You are now ready to use the instrument.
You can now enter the area and detect gases.
7. To locate the source of an odor, rotate the
center wheel until there is a uniform ticking
sound. Increased gas concentration will
cause an increase in the speed of the ticking
sound. As you approach the leak rotate the
wheel counter-clockwise to slow the speed.
Rotate clockwise to increase the speed
(indicating lower gas concentrations).
8. When your investigation is complete slide
the switch to the off position.
SENSIT
®
TKX
QUICK-START INSTRUCTIONS