THE SENSUS OMNI METER
The patented measurement principles of the OMNI
meter ensure enhanced accuracy ranges, an overall
greater accuracy, and a longer service life than any other
comparable class meter produced. The OMNI meter has
no restrictions in sustained ow rates within its continuous
operating range. The oating ball measurement technology
allows for ows up to its rated maximum capacity without
causing undue wear or accuracy degradation when installed
in any orientation.
ELECTRONIC REGISTER
The OMNI electronic register consists of a hermetically
sealed register with an electronic pickup containing no
mechanical gearing. The large character LCD displays AMR,
Totalization and a Resettable Test Totalizer. The electronic
register includes the following partial list of features:
AMR resolution units that are fully programmable
Pulse output frequency that is fully programmable
Integral customer data logging capability
Integral resettable accuracy testing feature compatible
with the UniPro testing Assistant Program
Large, easy-to-read LCD display that shows both
forward and reverse ow directions
10-year battery life warranty
REGISTER DISPLAY
1. Reading Mode
AMR: Shows the reported units
Total: Shows the total registration through the meter (all
8 digits)
Test: Shows the registration through the meter, but can
be reset to 0 to perform a test
2. AMR Digit Bar (4 to 8 Digits)—The AMR digit bar
shows which digits will be reported when the meter is
read through the communications interface.
3. Unit of MeasureGallon (GAL), Cubic Feet (CF),
Cubic Meter (M³), Imperial Gallon (IGAL), Acre Feet (AF)
4. AMR Value Multiplier (Only in AMR Mode)
5. Flow Icon:
Display Indicates
Flashing circle with + Positive Flow
Flashing circle with - Negative Flow
No Icon/Icon Not Flashing Flow Stopped
6. Battery IconThe Battery Icon will turn on when the
battery is near the end of line (≈11 years). AMR Digits
will sequentially blink before the battery dies (≈15 years).
WQG-10011-01
How to Read the OMNI
Quick Guide

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sensus OMNI and is the answer not in the manual?

Sensus OMNI Specifications

General IconGeneral
Protection RatingIP68
Temperature Range-40°C to +200°C
CommunicationModbus
Power SourceInternal battery
OutputPulse
Measurement PrincipleUltrasonic transit time