SPS-1500 Troubleshooting
7
Error
Possible Cause
Troubleshooting Step
DC-DC Bad or DC-DC
Chk - (Voltage measured
by SPS is not matching
what is sourced by SPS)
Bad Ground Connection
Low Resistance from Gauge
Signal to Ground
Excessive Gauge signal line
current
Faulty SPS
Check Downhole readings (Phase-Phase & Phase-Ground
(Reverse Polarity Megger))
Try alternate SPS power supply
Use voltmeter to confirm voltage MAX Voltage is over 45VDC.
DC-DC Bad or DC-DC
Chk - (El voltaje medido
por SPS no coincide con
el de SPS)
Mala conexión a tierra
Baja resistencia de la señal del
sensor a tierra
Corriente de línea de señal de
sensor excesiva
SPS defectuoso
Verifique las lecturas eléctricas del equipo de fondo (fase-
fase y fase-tierra (megóhmetro con polaridad inversa))
Pruebe una fuente de alimentación SPS alternativa
Use un mulltímetro para confirmar que el voltaje MÁX. sea
superior a 45 VCC.