SPS-1500 Troubleshooting
8
Error
Possible Cause
Troubleshooting Step
Baud Fast
(Gauge Data is changing
at a Rate higher than
expected)
Set voltage is too high
Motor noise affecting gauge
current modulation
Disable Auto Baud and raise Max Tool Baud to 8-10
Reboot or cycle power to restart analyzing stage
Disable Auto Volt/ Auto Analyze with DataWorks. Set voltage to
~60VDC.
Baud Fast
(Los datos del sensor
están cambiando a una
velocidad superior a la
esperada)
El voltaje configurado es
demasiado alto
Ruido del motor afecta a la
modulación actual del sensor
Desactive Auto Baud y aumente Max Tool Baud a 8-10
Reiniciar o apagar y encender para reiniciar la etapa de análisis
Desactive Auto Volt / Auto Analyze con DataWorks. Establezca
el voltaje en ~ 60 VCC.