SPS-1500 Troubleshooting
9
Error
Possible Cause
Troubleshooting Step
Low Amps
(Gauge current is lower
than expected)
Disconnected from tool
High resistance connection at
motor WYE point to gauge
Blown Signal fuse
Low amp setting set to high
Check Downhole readings (Phase-Phase & Phase-Ground
(Reverse Polarity Megger))
Check all connection(s)
Check Signal fuse
Check Setting of Low amp with DataWorks (15VDC Nominal)
Check Setting of High amp with DataWorks (25VDC Nominal)
Low Amps
(La corriente del sensor es
mas baja de la esperada)
Sensor no esta conectado
Conexión de alta resistencia en el
motor WYE punto a sensor
Fusible de señal abierto
Ajuste de amperaje bajo
establecido en alto
Verifique las lecturas del fondo del pozo (fase-fase y fase-tierra
(megóhmetro con polaridad inversa))
Verifique todas las conexiones
Compruebe el fusible de señal
Verifique el ajuste de amperaje bajo con DataWorks (15 VDC
nominal)
Verifique la configuración de alto amperaje con DataWorks (25
VDC nominal)