SPS-1500 Troubleshooting
10
Error
Possible Cause
Troubleshooting Step
High Amps
(Gauge current is higher
than expected)
Poor Wellhead grounding
Excessive Gauge Signal Line
Current or injection of noise from
motor at wye point.
Connect to the SPS with “DataWorks” software to manually set
the following current settings for the gauge:
- Check Setting of Low amp (15mA normally for SPS-1500 and 2-
8mA normally for SPS-1501)
- Check Setting of High amp (25mA normally for SPS-1500)
Verify Downhole readings (Phase to Phase, Phase-Ground
(Reverse Polarity Megger))
Replace the SPS-1500
High Amps
(La corriente del sensor es
mas alta de la esperada)
Conexión a tierra del cabezal de
pozo deficiente
Corriente de línea de señal del
sensor excesivo o ruido del motor
en el punto estrella.
Conéctese al SPS con el software "DataWorks" para establecer
manualmente las siguientes:
- Compruebe la configuración de Low Amp (15 mA normalmente
para SPS-1500)
- Compruebe la configuración de High Amp (25 mA normalmente
para SPS-1500 y 22-26 mA normalmente para SPS-1501)
Verifique las lecturas del equipo de fondo (fase a fase, fase-
tierra (megóhmetro con polaridad inversa))
Reemplace el SPS-1500

Other manuals for Sercel GRC Spy Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sercel GRC Spy Pro and is the answer not in the manual?

Sercel GRC Spy Pro Specifications

General IconGeneral
BrandSercel
ModelGRC Spy Pro
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals