Questions and Answers

  • W
    William SimpsonAug 12, 2025
    How to fix Seres OL Measuring Instruments when it is not starting?
    • V
      Vicki ThomasAug 12, 2025
      If your Seres OL Measuring Instruments device isn't starting, there might be a few reasons. First, check the mains power supply. If that's not the issue, check the power supply output (24V). Lastly, verify the power supply connector to ensure the panel is properly supplied.
  • W
    whillAug 19, 2025
    What to do if the vessel is not emptied in Seres OL Measuring Instruments?
    • T
      thompsonronaldAug 19, 2025
      If the vessel in your Seres OL Measuring Instruments is not emptying or is overflowing, it could be due to a blocked threshold. Check the pipe condition, both inside and outside. Another potential cause is a blocked emptying pipe or a faulty emptying solenoid valve. Ensure that the emptying pipe isn't pinched when the door is closed. If it is, unblock it.
  • L
    Lisa AllenAug 25, 2025
    Why does the "Water default" alarm keep setting off on my Seres OL Measuring Instruments?
    • J
      Jordan JohnsonAug 25, 2025
      If the "Water default" alarm is triggered on your Seres OL Measuring Instruments even when the sample is correctly provided, it could be due to a malfunctioning fill-in solenoid valve. Check that the fill-in solenoid valve is plugged in correctly. Alternatively, one or more hydraulic pipes might be blocked or pinched, so inspect the pipe condition.
  • M
    Michael CarpenterAug 27, 2025
    How to troubleshoot vessel not filling in Seres OL Measuring Instruments?
    • S
      Sean Stone MDAug 27, 2025
      If the vessel in your Seres OL Measuring Instruments isn't filling, start by checking that the pumps are connected correctly and that they are unblocked. Also, inspect the hydraulic pipes for any blockage or pinching.
  • D
    Derrick YangAug 31, 2025
    What to do if application is not launching in Seres OL Measuring Instruments?
    • A
      Ashley SuarezAug 31, 2025
      If the application isn't launching on your Seres OL Measuring Instruments, but the device is starting, the issue may be with the PC Panel. Ensure that the panel is correctly supplied.
  • R
    ryansteinSep 3, 2025
    What to do if the measure is not updated on Seres OL Measuring Instruments?
    • C
      Christopher AtkinsSep 3, 2025
      If the measure is not updating on your Seres OL Measuring Instruments, it might be because the new measure is the same as the first one, or the measuring cycle is in a stop or rest position. Try launching the measuring cycle again.
  • R
    Rachel WashingtonSep 7, 2025
    What to do if the screen does not work in Seres OL Measuring Instruments?
    • D
      David NicholsSep 7, 2025
      If the screen on your Seres OL Measuring Instruments isn't working, shut down and restart the device.
  • E
    Eric RogersNov 15, 2025
    What to do if Seres OL Measuring Instruments gives a bad measure?
    • T
      todd94Nov 15, 2025
      If your Seres OL Measuring Instruments are providing bad measures, consider these potential causes and solutions: * If there are bubbles in reagents pipes, prime the pump until the bubbles are gone. Also, check the reagent pipes for any piercing and rinse the vessel correctly. * If reagents are sucked badly, ensure that reagent pipes are correctly immersed in reagent containers and air intake is sufficient. * Check the use-by date of the reagents and ensure they have been stocked in appropriate conditions. If not, change reagents. * Verify the correspondence between reagents pipes (each pipe is dedicate to a reagent). * Make sure that the pipe inside the pump is well positioned and undamaged. * Check pipe condition (inside and outside) if the sewer is blocked. * If the empty...