15
www.lakeland.co.uk
Troubleshooting Guide
PROBLEM POSSIBLE REASONS & SOLUTIONS
Sonic Duo
™
is squirting
foam from the spray nozzle.
1. The Reusable Bottle is not firmly inserted into the unit. Make sure that
you hear an audible “Click” when you insert the Reusable Bottle into the
appliance.
2. There may be air in the system. Hold down the spray button for 5 to 10
seconds to flush the system.
Sonic Duo
™
doesn’t spray.
1. Make sure that the Reusable Bottle is inserted all the way in. You should
hear an audible “Click” when inserted.
2. Check that there is enough cleaning solution in the Reusable Bottle. If
not, add more.
3. The bottle cap on the Reusable Bottle may need to be cleaned. Remove
it from the Reusable Bottle and rinse it under running water and then
replace it onto the Reusable Bottle.
4. There may be air in the system. Hold down the spray button for 5 to 10
seconds until solution comes out of the spray nozzle.
5. The colored spray nozzle at the front of the unit where the spray comes
out may be clogged. Clean the spray nozzle by removing it from the unit.
To remove it, grip the small lips at the top and bottom of the spray nozzle
and turn counterclockwise. Run the spray nozzle under warm water to
clean it out. Reinsert the spray nozzle by lining up its grooves with the
inside of the nozzle hole. Turn clockwise until the lips return to the top
and bottom positions.
Sonic Duo
™
turns off when
the handle is lowered.
1. The Sonic Duo
™
automatically turns off when the handle is lowered to
low. This is a safety mechanism to ensure that the machine will turn off
if it is dropped. To keep the Sonic Duo
™
on when cleaning under low
profile items, simply twist the handle to the left or right and engage the
swivel. When the handle is swivelled and lowered, the Sonic Duo
™
will
remain on.
The cap of the Reusable Bottle
is stuck inside the Sonic
Duo
™
after the bottle was
removed.
1. To remove the cap, hold center valve of the cap with your fingers and
gently pull it out. If it doesn’t come out easily, use a set of long nose
pliers for leverage. Be careful not to crack the center valve when applying
pressure and lifting up.
The Reusable Bottle fell out.
1. The Sonic Duo
™
is not meant to be turned upside down. When upside-
down, the Reusable Bottle is at risk for falling out of its cradle. Please do
not turn the Sonic Duo
™
upside-down. If it is necessary to turn the unit
upside-down, remove the Reusable Bottle first.
Sonic Duo
™
turns off on
its own.
This unit is equipped with an automatic protector. If for some reason your
appliance overheats, the protector will automatically turn the unit off. Should
this occur, perform the following steps to restart the appliance:
1. Move the switch to the “O” (Off) position.
2. Unplug.
3. Allow the unit to cool for around 45 minutes.
4. Plug in.
5. Turn the switch on to restart.