20N-S100S
CN20S10
M01 MS LEVEL 00-0F 0A
M02 MTS-VCO 00-3F 20
M03 FILTER 00-3F 1C
M04 LOW SEPARATION 00-3F 20
M05 HIGH SEPARATION 00-3F 1B
SERVICE
POSITION
ADJUST ITEM
DATA
RANGE
INITIAL VALUE
ADJUSTMENT CONTENTS
Table - D
FEATURE
Note: Refer to the SERVICE ADJUSTMENT for each corresponding values.
IC2001
IC2101 X
CRT X
IC201
Data is stored in IC2101.
Adjust items related to picture tube only.
Holding down both the Vol-up/Ch-down buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2101.
Table - E
The adjustment is needed to compensate for characteristics
of parts including IC201.
Holding down both the Vol-up/Ch-down buttons on the TV
set in the service mode for more than 2 seconds will
automatically write the above initial values into IC2101.
X
X
ADJUSTMENT
NECESSARY
UNNECESSARY
PART REPLACED