EasyManua.ls Logo

Sharp 21F-PT220 - Page 22

Sharp 21F-PT220
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21F-PD250 / 21F-PT220 / 21F-PA18 / 21F-PA18(B)
3 – 19
No.
Adjustment point
Adjustment procedure/conditions Waveform and others
SUB-
BRIGHTNESS
(to be done
after screen,
white balance
adj)
(12C BUS
CONTROL)
3
SUB-
CONTRAST
(to be done
after screen,
white balance
adj,
sub-bright-
ness adj)
(I
2
CBUS
CONTROL)
4
1) Receive the “Monoscope Pattern” signal.
2) Press R/C to set Picture NORMAL condition.
3) Connect the DC miliammeter between TP 603
(+)&TP602(-).
(Full Scale: 3mA Range)
4) Beam current must be within 1100
±
100
µ
A.
Beam Current
Check
5
Dark White
WINDOW PATTERN SIGNAL
White
WINDOW PATTERN SIGNAL
1) In Window Pattern Signal condition.
Using Minolta Color Analyzer CA-100, let the
gun point at Dark White position (as attach
drawing), adjust V06 Bus data until
LUMINANCEY=3±0.5cd/m2.
2)
1) In Window Pattern Signal condition.
Using Minolta Color Analyzer CA-100, let the
gun point at White position (as attach drawing),
adjust V04 Bus data until LUMINANCE Y = 160
±10cd/m2
2)

Table of Contents

Related product manuals