EasyManua.ls Logo

Sharp 27C240 - Control Operation and EZ SETUP

Sharp 27C240
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Table - A
Below are the ranges and initial values for each adjustment and in each categories.
DEF
D01 H-PHASE 00-1F 0C
D02 V-SIZE 00-7F 40
D03 V-POSITION 00-3F 20 Must be "20"
D04 CC-POSITION 00-FF 1A
D05 V-LINEARITY 00-1F 10 Must be "13"
D06 V-S-CORRECTION 00-1F 10 Must be "14"
SERVICE
POSITION
ADJUST ITEM
DATA
RANGE
INITIAL VALUE
ADJUSTMENT CONTENTS
Table - B
TUNER TYPE
CRT
VB68ADT2506*S
VTUVT1T5UF202 13
*2: type of tuner
Below are the adjustments ranges and initial values for FIX VALUE category.
FIX VALUE
F01 OPTION 1 00-FF B1 *1
F02 OPTION 2 00-FF 07 27
F03 E-SAVE 00-3F 2A 2A
F04 TUNER SETUP 00, 01 00 00
F05 R-TONE RD 00-7F 03 03
F06 R-TONE BD 00-7F 7C 7C
F07 B-TONE RD 00-7F 00 00
F08 B-TONE BD 00-7F 04 04
F09 FM LEVEL 00-1F 16 16
F10 AFC GAIN 00, 01 00 00
F11 G DRIVE 00, 0F 0F 0F
F12 FBT BLK SW 00, 01 01 01
F13 V COMP 00-07 07 07
F14 OSD CONT 00-03 01 01
F15 SHARPNESS 00-3F 0D *2
F16 FLT SYS 00-07 01 01
F17 KILLER OP 00-07 02 02
F18 PRE SHOOT 00-03 00 00
F19 CORING 00-03 04 04
F20 DC REST 00-03 02 02
F21 BS START 00-03 01 01
F22 BS GAIN 00-03 01 01
F23 ABL START 00-07 00 00
F24 R/B ANGLE 00-0F 08 08
F25 H BLK R 00-0F 03 03
F26 H BLK L 00-0F 00 00
F27 YC 00-07 05 04
SERVICE
POSITION
ADJUST ITEM
DATA
RANGE
INITIAL VALUE
(Hex)
ADJUST ITEM
MODEL
27C240
OPTION 1 B1
*1: adjust item
27C240

Other manuals for Sharp 27C240

Related product manuals