EasyManua.ls Logo

Sharp AE-A079E - Electrical and Wiring Information; Indoor and Outdoor Unit Wiring Diagrams

Sharp AE-A079E
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AY/AE-A079E
AY/AE-A099E
4
WIRING DIAGRAMS
Figure W-1. Wiring Diagram for AY-A079E and AY-A099E
Figure W-2. Wiring Diagram for AE-A079E
THERMISTOR
(PIPE TEMP.)
THERMISTOR
(ROOM TEMP.)
LOUVER
MOTOR
1
2
3
4
5
6
CN5
CN3
CN101
BCN1
CN2
BCN2
CN201
RECEIVER
& LED UNIT
SWITCH
UNIT
THERMAL FUSE
TRANSFORMER
CONTROL 
BOARD 
UNIT 2
WH
WH
RE
RE
FAN MOTOR 
CAPACITOR
400V 1µF
FAN MOTOR
R.P.M
SIGNAL
BL
BL
GR
RE
CN6
CN7
CN4
CN1
SSR
RY2
RY3
(B)
(A)
(F)
(E)
NR
VARISTOR
RY
CONTROL BOARD UNIT 1
OUT
C.T.
IN
BK
OR
PU
BL
250V
FUSE 
T2.5A
INDOOR UNIT
TERMINAL 
BOARD 2
OUTDOOR UNIT
TERMINAL
BOARD
EVAPORATOR
THERMAL 
FUSE
TERMINAL
BOARD 1
POWER
SUPPLY
CORD
BR
BL
G(Y)
N
L
G(Y)
G(Y)
G(Y)
N
1
2
3
UNIT TO UNIT CORD
BL
BR
BL
BK
BL
BR
GR
G(Y)
RE
WH
OR
PU
: BLACK
: BLUE
: BROWN
: GRAY
: GREEN–YELLOW
: RED
: WHITE
: ORANGE
: PURPLE
N
5
7
1
2
1
2
3
5 3 1
INDOOR UNIT
TERMINAL BOARD 2
TERMINAL 
BORAD 1
UNIT TO UNIT CORD
OUTDOOR UNIT
TERMINAL BOARD
CONDENSER
THERMAL 
FUSE
FAN
MOTOR
VALVE
COIL
FAN MOTOR
CAPACITOR
400V 1.5µF
COMPRESSOR
MOTOR
MOTOR PROTECTOR
RUNNING
CAPACITOR
370V 25µF
BK
BK
WH
RE
R
BL
RE
BL
BL
BK
BL
RE
RE
G(Y)
G(Y)
C
S
I
2
3
N
I
2
3
N
N
L
BK
BL
G(Y)
RE
WH
:BLACK
:BLUE
:GREEN-YELLOW
:RED
:WHITE 