CHAPTER 1. SPECIFICATION
[1] SPECIFICATION............................................ 1-1
[2] EXTERNAL DIMENSION............................... 1-3
[3] WIRING DIAGRM .......................................... 1-4
[4] ELECTRICAL PARTS .................................... 1-4
CHAPTER 2. EXPLAMATION OF CIRCUIT AND OP-
ERATION
[1] BLOCK DIAGRAMS....................................... 2-1
[2] MICROCOMPUTER CONTROL SYSTEM........ 2-3
[3] FUNCTION..................................................... 2-8
CHAPTER 3. FUNCTION AND OPERATION OF PRO-
TECTIVE PROCEDURES
[1] PROTECTION DEVICE FUNCTIONS AND
OPERATIONS................................................ 3-1
[2] AIR CONDITIONER OPERATION IN
THERMISTOR ERROR ................................. 3-3
[3] THERMISTOR TEMPERATURE CHAR-
ACTERISTICS ............................................... 3-5
[4] HOW TO OPERATE THE OUTDOOR
UNIT INDEPENDENTLY................................ 3-6
[5] GENERAL TROUBLESHOOTING CHART........ 3-6
[6] MALFUNCTION (PARTS) CHECK METH-
OD .................................................................3-8
[7] OUTDOOR UNIT CHECK METHOD...........3-10
[8] TROUBLESHOOTING GUIDE ....................3-13
REPLACEMENT PARTS LIST
SERVICE MANUAL
AYXP9GHR
CONTENTS
Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the
safety and performance of the set.
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
TopPage
SPLIT TYPE
ROOM AIR CONDITIONER
OUTDOOR UNIT
AE-X9GHR
AE-X12GHR
MODELS
INDOOR UNIT
AY-XP9GHR
AY-XP12GHR
In the interests of user-safety (Required by safety regulations in some countries) the set should be
restored to its original condition and only parts identical to those specified should be used.

Questions and Answers:

Sharp AE-X12GHR Specifications

General IconGeneral
BrandSharp
ModelAE-X12GHR
CategoryRoom air conditioner
LanguageEnglish

Summary

Chapter 1: Specification

Model Specifications

Detailed specifications for AY-XP9GHR/AE-X9GHR models.

External Dimensions

Diagrams illustrating indoor and outdoor unit dimensions and measurements.

Wiring Diagrams and Self-Diagnosis

Wiring diagrams for indoor and outdoor units, including self-diagnosis indications.

Electrical Parts List

Lists of electrical parts for indoor and outdoor units with model numbers.

Chapter 2: Circuit and Operation Explanation

Block Diagrams

High-level block diagrams illustrating the system's functional connections.

Microcomputer Control System

Explanation of the microcomputer control system and its functions.

Unit Functions

Details on the operational functions of the air conditioner.

Chapter 3: Protective Procedures

Protection Device Functions

Overview of protection device functions and their operational aspects.

Thermistor Error Operation

How the unit operates when a thermistor error occurs.

Thermistor Temperature Characteristics

Characteristics of thermistors related to temperature.

Independent Outdoor Unit Operation

Instructions for operating the outdoor unit independently.

General Troubleshooting Chart

A general chart for troubleshooting common issues.

Troubleshooting Guide

Self-Diagnosis Function and Display

How to use the self-diagnosis function and interpret its displays.

Erroneous Wiring Symptoms

Symptoms and diagnosis for errors caused by incorrect wiring.