AYXP9GHR
3 – 15
Indoor/
outdoor 
units in 
complete 
shutdown
6 times 6 -0 Outdoor unit DC DC overcurrent error (1) IPM continuity check (1) Replace the outdoor 
unit control PWB 
assembly.
(2) Check the IPM and heat 
sink for secure installation.
(2) Correct the installa-
tion (tighten the 
screws).
(3) Check the outdoor unit fan 
motor for proper rotation.
(3) Replace the outdoor 
unit fan motor.
(4) No abnormality found in 
above inspections (1) 
through (3).
(4) Replace the outdoor 
unit control PWB 
assembly.
(5) No abnormality found in 
above inspections (1) 
through (4).
(5) Replace the compres-
sor.
-1 IPM pin level error Check the IPM is attached 
correctly to the outdoor 
unit control PWB.
Replace the outdoor 
unit control PWB 
assembly.
Indoor/
outdoor 
units in 
complete 
shutdown
7 times 7 -0 Outdoor unit AC AC overcurrent error (1) Check the outdoor unit air 
outlet for blockage.
(1) Ensure unobstructed 
air flow from the out-
door unit air outlet.
(2) Check the outdoor unit fan 
for proper rotation.
(2) Check the outdoor unit 
fan motor.
-1 AC overcurrent error 
in OFF status
(1) IPM continuity check (1) Replace the outdoor 
unit control PWB 
assembly.
-2 AC maximum cur-
rent error
(1) Check the outdoor unit air 
outlet for blockage.
(1) Ensure unobstructed 
air flow from the out-
door unit air outlet.
(2) Check the outdoor unit fan 
for proper rotation.
(1) Check the outdoor unit 
fan motor.
-3 AC current defi-
ciency error
(1) Check if there is an open-
circuit in the secondary 
winding of the current 
transformer of the outdoor 
unit control PWB.
(1) Replace the outdoor 
unit control PWB 
assembly.
(2) Check if the refrigerant 
volume is abnormally low.
(2) Charge the specified 
amount of refrigerant.
(3) Check if the refrigerant 
flows properly.
(3) Correct refrigerant 
clogs.
(2-way valve, 3-way 
valve, pipe, expan-
sion valve)
Indoor/
outdoor 
units in 
complete 
shutdown
9 times 9 -0 Outdoor unit 
cooling/heating 
switchover
Thermistor installa-
tion error or 4-way 
valve error
(1) Check to make sure out-
door unit thermistor TH2 
(heat exchanger) and TH5 
(2-way valve) are installed 
in correct positions.
(1) Correct the installa-
tion.
(2) Measure resistance of 
thermistors TH1 and TH5.
(2) Replace the ther-
mistor assembly.
(3) Check the 4-way valve for 
proper operation.
(3) Replace the 4-way 
valve.
(4) No abnormality found in 
above inspections (1) 
through (3).
(4) Replace the outdoor 
unit control PWB 
assembly.
-3 Torque control error (1) Check if the refrigerant 
volume is abnormally low.
(1) Change the specified 
amount of refrigerant.
(2) Check the 4-way valve for 
proper operation.
(2) Replace the 4-way 
valve.
(3) check to see compressor 
type is correct.
(3) Replace the compres-
sor with the correct 
part.
Status of 
indoor/
outdoor 
units
Indication 
by LED1 
on out-
door unit 
*2
Malfunction 
No. dis-
played on 
main unit 
display sec-
tion *1
Content of diagnosis Inspection location/method Remedy
Main 
cate-
gory
Sub-
cate-
gory
Main category Sub-category