AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
(4)
Defrost
stop
2-2
(1)
(2
(3
4)
(5
~—
~—
When
defrosting
time
exceeds
13
minutes
When
the
temperature
of
the
outdoor
heat
exchanger
rises
above
approximately
7°C
Defrost
stop
is
determined
by
either
of
the
above
conditions,
and
the
compressor
is
stopped.
At
the
same
time,
the
outdoor
fan
go
ON. The
compressor
is
reactivated
in
the
heating
cycle
1
minute
after
it
was
stopped,
and
normal
control
resumes.
Frequency
control
AC
current
peak
control
[Nethe
eeey
aa
Control
for
prevention
of
indoor
heat
exchanger
overheating.
if
the
temperature
of
the
indoor
heat
exchanger
exceeds
the
overheating
prevention
line
1
or
2
during
heating,
the
operating
frequency
is
lowered
by
approximately
5
to
10
Hz.
After
that,
the
frequency
is
lowered
by
approximately
5Hz
once
every
60
seconds
or
10
Hz
once
every
60
seconds.
When
the
temperature
of
the
indoor
heat
exchanger
goes
below
the
overheating
prevention
line
1,
the
frequency
is
raised
by
approximately
5
Hz
once
every
60
seconds,
and
normal
operation
is
restored.
If
the
frequency
is
lowered
to
minimum
frequency
without
the
temperature
of
the
outdoor
heat
exchanger
decreasing
and
this
condition
lasts
for
1
minute,
the
compressor
will
be
stopped.
Overheating
prevention
line
1
(Lower
5Hz)
i
AE-X08CR
= 6
ss
Operating
frequency
AE-X10CR
130Hz
112Hz
105Hz
AE-X13CR
130Hz
112Hz
During
normal
operation
.
44.84
51.87
During
full
power
operation
47.39
50.95
Overheating
prevention
line
2
(Lower
10Hz)
AE-XOBCR
|
130Hz~]
112Hz~
|
105Hz~]
97Hz~
|
SOHz~
|
43Hz~|
37Hz~
|
~37Hz
AE-X13CR
130H2z
|
112Hz
|
105Hz
|
97Hz 50Hz
43Hz
*C
4959
|
4959
|
5329
|
5625
|
57.27
|
5625
|
55.24
|
47.39
During
full
power
operation
[C}
51.87
|
5187
|
53.74
|
58.85
|
59.94
|
58.85
Control!
for
prevention
of
outdoor
heat
exchanger
overheating.
If
the
temperature
of
the
outdoor
heat
exchanger
exceeds
the
overheating
prevention
line
1
or
2
during
cooling,
the
operating
frequency
is
lowered
by
approximately
5
to
15
Hz.
After
that,
the
frequency
is
lowered
by
approximately
5
once
every
60
seconds
or
approximately
15Hz
once
every
60
seconds.
When
the
temperature
of
the
outdoor
heat
exchanger
goes
below
the
overheating
prevention
clear
line,
the
frequency
is
raised
by
approximately
5
Hz
once
every
60
seconds,
and
normal
operation
is
restored.
If
the
frequency
is
lowered
to
minimum
frequency
without
the
temperature
of
the
outdoor
heat
exchanger
decreasing
and
this
condition
lasts
for
1
minute,
the
compressor
will
be
stopped.
Overheating
prevention
line
1
55°C
_|
Lower
5Hz
once
every
60
seconds
|
Overheating
prevention
line
2
|
57°C
|
Lower
15Hz
once
every
60
seconds
|
|
Overheating
prevention
clear
line
|
54°C
|
|
Operating
frequency
Control
for
prevention
of
discharge
overheating
If
the
discharge
temperature
exceeds
approximately
105°C
during
compressor
operation,
the
operating
frequency
is
lowered
by
approximately
5
Hz.
After
that,
the
frequency
is
lowered
by
approximately
5
Hz
once
every
60
seconds.
When
the
discharge
temperature
goes
below
approximately
104°C,
the
frequency
is
raised
by
approximately
5
Hz
once
every
60
seconds,
and
normal
operation
is
restored.
If
the
frequency
is
lowered
to
minimum
frequencywithout
the
discharge
temperature
decreasing
and
this
condition
lasts
for
1
minute,
the
compressor
will
be
stopped.
Control
for
prevention
of
indoor
heat
exchanger
freezing
If
the
temperature
of
the
indoor
heat
exchanger
goes
below
approximately
5°C
during
cooling(only
Full
power
operation),
the
operating
frequency
is
lowered
by
approximately
5
Hz.
After
that,
the
frequency
is
lowered
by
approximately
5
Hz
once
every
60
seconds.
When
the
temperature
of
the
indoor
heat
exchanger
rises
above
approximately
5°C,
the
frequency
is
raised
by
approximately
5
Hz
once
every
60
seconds,
and
normal
opération
is
restored.
If
the
temperature
of
the
indoor
heat
exchanger
goes
down
to
approximately
0°C
and
this
condition
continues
for
4
minutes,
the
compressor
is
stopped.
When
the
temperature
rises
above
approximately
2°C,
normal
operation
is
restored.
23