AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
FUNCTIONS
AH-X08CR/X10CR/X13CRare
not
provided
with
the
heating
function.
1.
INDOOR
UNIT
1-1
Temperature
Adjustment
a.
Normal
control
Proportional
control
(P
control)
When
the
temperature
zone
changes,
this
control
changes
the
frequency
by
one
rank
to
move
closer
to
the
set
value.
Integral
control
(I
control)
When
the
temperature
zone
has
set
time
in
the
same
zone,
this
control
changes
the
frequency
by
one
rank
to
move
closer
to
the
set
value.
(Excluding
the
h
zone.)
b.
Initial
control
The
initial
frequency
is
determined
as
shown
in
the
tables
below
based
on
the
difference
between
the
temperature
adjustment
setting
at
the
beginning
of
operation
and
the
room
temperature.
After
operation
begins,
normal
control
is
performed
and
therefore
the
correspondences
in
the
tables
below
will
not
hold.
Cooling
43.33
+2.66
+2.00
41.33
+0.66
SET
VALUE
-0.66
KF,
|e
TIa]|
+l
ejpalo
-1.66
Heating
k
$1.33
+0.66
SET
VALUE
2
bo2)
eo
1.33
-2.00
-2.67
-3.33
-4.00
-4.66
-$.33
Nim/oO/o/aQ/}o;~/oa}]aj{
-
+2.66
+2.00
+1.33
+0.66
MEMORY
SET
VALUE
- - -
Cooling
Heating
Room/Frequency
Frequency
Code
OFF
(Hot
keep
fan)
Although
the
initial
value
of
the
h
zone
is
1,
it
changes
to
2
after
a
lapse
of
15
minutes.
Full
power
operation
only
c.
Temperature
adjustment
The
temperature
adjustment
range
is
changed
by
changing
the
operating
mode
with
the
operation
switch.
(1)
Heating
If
the
room
temperature
is
in
the
z
zone
when
operation
begins,
proportional/integral
control
is
not
performed,
and
the
machine
runs
at
frequency
code
c
full
power
until
the
i
zone
is
reached.
When
the
i
zone
is
reached,
the
frequency
changes
to
the
frequency
code
determined
by
fuzzy
caiculation,
and
after
that
proportional/integral
control
is
performed.
(2)
Cooling
If
the
room
temperature
is
in
the
c
zone
when
operation
begins,
proportional/integral
control
is
not
performed,
and
the
machine
runs
at
frequency
code
9
power
until
the
i
zone
is
reached.
When
the
h
zone
is
reached,
the
frequency
changes
to
the
frequency
code
determined
by
fuzzy
calculation,
and
after
that
integral
control
is
performed.
(3)
Dry
After
operation
begins,
2
minutes
(running
at
the
h
zone)
of
the
room
temperature
is
stored
in
memory,
and
that
becomes
the
set
value.
(4)
Circulation
The
frequency
code
0
is
sent
to
the
outdoor
machine,
and
only
the fan
of
the
indoor
machine
runs,
the
compressor
does
not
run.
1-2
Indoor
fan
control
This
control
uses
the
thermistor
for
the
indoor
heat
exchanger
to
control
cold
air
blowing
prevention,
the
indoor
fan,
and
overheating
prevention.
Differential
3°C
Cold
air
blowing
prevention
line
Temperature
of
indoor
heat
exchanger

Questions and Answers: