AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
h)
After
securing
the
caps
on
the
control
valves,
check
the
capsAf
periphery
if
there
is
any
gas
leakage.
9
@ @
©
Compound
pressure
gauge
-76cmHg
(6)
Handle
Lo
we
Gauge
manifold
Handle
Hi
(always
closed)
()
Charge
hose
ae
(2)
Charge
hose
(3)
Control
valve
(2-way)
Caution:
e
Be
sure
to
use
the
vacuum
pump,
adapter
and
gauge
manifold
to
refer
to
tion
manuals
beforehand.
|
Ascertion
that
the
vacuum
pump
is
fille
the
level
designated
on
the
oil
gauge.
@
Service
port
(4)
Control
valve
(3-way)
Fig.
6
Configuration
of
Air
Purge
by
Vacuum
Pump
(2)
Additional
Refrigerant
Charging
Required
for
Refrigerant
Piping
Length
Longer
Than
Standard
Length
(The
following
steps
should
be
taken
following
the
step
e)
in
(1)
above.
See
Fig.
7)
a)
Setthe
refrigerant
cylinder
to
the
electronic
balance,
and
connect
the
connecting
hoses
on
the
cylinder
and
electronic
balanceAfs
connecting
port.
Be
sure
to
make
setting
so
that
liquid
con
be
charged.
When
using
a
cylinder
equipped
with
a
siphon,
liquid
can
be
charged
without
turning
it
upside
down.
b)
Connect
the
gauge
manifoldAfs
charge
hose
to
the
electronic
balanceAfs
connecting
port.
@
@
c)
Open
the
refrigerant
cylindesAfs
valve,
and,
after
opening
the
charging
valve
a
little,
close
it.
@ @
d)
After
making
zero
(0)
adjustment,
open
the
charging
valve
and,
by
opening
the
gauge
maniflod's
valve
Lo,
charge
the
liquid
refrigerant.
@ ©
e)
When
the
designated
amount
of
refrigrant
could
not
be
charged,
make
additional
charging
bit
by
bit
by
cooling
operation
(for
the
amount
of
each
addition,
follow
the
instruction
manual
prepared
by
the
equipment
manufacturer)
.
If
the
first
additional
charging
was
not
enough,
make
the
second
additional
charging
after
about
one
miunte
in
the
same
manner
as
the
first
additional
charging.
Be
sure
never
to
charge
a
large
amount
of
liquid
refrigerant
at
once
to
the
unit
in
cooling
mode,
since
liquid
is
charged
from
the
gas
siede.
f)
After
charging
liquid
refrigerant
into
the
air
conditioner
by
closing
the
charging
valve,
stop
operation
by
fully
closing
the
gauge
manifold's
valve
Lo.
@
©
g)
Quickly
remove
the
charge
hose
from
the
service
port.
©
When
stopped
halfway,
refrigerant
being
cycled
will
be
released.
57
|