EasyManua.ls Logo

Sharp AY-X127E - Page 33

Sharp AY-X127E
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AH-X127E
AU-X127E
AY-X127E
AE-X127E
33
Indoor side
Standard conditions: 
Dry-bulb Temp. (˚C) Relative Humidity (%)
27
20
Cooling
Heating
47
Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%)
35
7
40
87
AY-X127E
Temperature at each part and pressure in 3-way valve
Operation 
mode
Cool
(Max.)
Heat
(Max.)
Cool Heat
1
2
3
4
3-way valve
pressure
(kg/cm
2
G)
107˚C
46˚C
13˚C
5˚C
4.2
103˚C
0˚C
39˚C
-1˚C
20.0
69˚C
44˚C
14˚C
12˚C
6.0
55˚C
2˚C
32˚C
2˚C
12.7
111 more than120 50 settle 50 settle
AY-X127E
No.
Hz
Capillary tube A
O.D I.D. L
ø3.2 ø1.8 1100
Capillary tube B ø3.2 ø1.8 500
AY-X127E
Dimension of Capillary tube

Related product manuals