3 - 3
Problem 
symptom
Outdoor 
unit 
indication 
(LED1)
Indoor unit
Malfunction 
No.*
Content of diagnosis Check point Action
o
Lamp Main Sub Main Sub
Indoor and 
outdoor 
units do not 
operate.
6-time O O O O O Timer (Orange) 6 0 Outdoor unit
DC Current
DC over current 
error
Go to “DC Over Current Error (6-0 error)”.
O O Operation (
Green
)
Plasmacluster (Blue)
O O O O O Timer (Orange) 1 IPM pin level error Check the IPM is attached 
correctly to the outdoor unit 
IPM PWB.
Replace the outdoor 
unit IPM PWB 
assembly.
O O Operation (
Green
)
O Plasmacluster (Blue)
Indoor and 
outdoor 
units do not 
operate.
7-time O O O O O Timer (Orange) 7 0 Outdoor unit
AC Current
AC over current error 1) Ensure unobstructed air 
unit air outlet.
2) Check the outdoor unit 
fan motor.
1) Ensure unobstructed 
outdoor unit air 
outlet.
2) Check the outdoor 
unit fan motor.
O O O Operation (
Green
)
Plasmacluster (Blue)
O O O O O Timer (Orange) 1 AC current error 
when OFF
1) IPM continuity check 1) Replace the outdoor 
IPM PWB
O O O Operation (
Green
)
O Plasmacluster (Blue)
O O O O O Timer (Orange) 2 AC maximum current 
error
1) Ensure unobstructed air 
unit air outlet.
2) Check the outdoor unit 
fan motor.
1) Ensure unobstructed 
outdoor unit air 
outlet.
2) Check the outdoor 
unit fan motor.
O O O Operation (
Green
)
O Plasmacluster (Blue)
O O O O O Timer (Orange) 3 AC current 
1) Replace the outdoor unit 
control PCB assembly.
amount of refrigerant.
3) Correct refrigerant clogs. 
(Stop valve, pipe, 
expansion valve)
1) Replace the outdoor 
unit control PCB 
assembly.
amount of refriger-
ant.
3) Correct refrigerant 
clogs. (Stop valve, 
pipe, expansion 
valve)
O O O Operation (
Green
)
O O Plasmacluster (Blue)
Indoor and 
outdoor 
units do not 
operate.
8-time O O O O O Timer (Orange) 8 0
0
Abnormal 
wire check
Abnormal wire check 
error
1) Check the expansion 
valve.  
2) Are four expansion 
valves connected by 
mistake.
3) Check the wiring 
between units.
1) Replace the outdoor 
control board 
assembly.
2) Reattach
3) Check the wiring 
between units.
O Operation (
Green
)
Plasmacluster (Blue)
OOOOO
O
Timer (Orange)
O Operation (
Green
)
Plasmacluster (Blue)
Indoor and 
outdoor 
units do not 
operate.
9-time
O O O O O Timer (Orange)
9
4 Cycle 
temperature
4 way valve error or 
Gas leak error
1) Check the unit thermistor 
TH2 (exchange) and 
TH3 (pipe temperature) 
are installed in correct 
portions.
2) Check if the refrigerant 
volume is abnormally 
low.
3) Check the 4-way valve 
for proper operation.
1) Correct the 
installation.
2) Change the 
refrigerant.
3) Replace the 4-way 
valve.
O O Operation (
Green
)
O Plasmacluster (Blue)
AY-XPC15PU
Cycle
temperature
Thermistor 
installation error 
or 4-way valve
 
error.
1)Check the ther-
mistor (heat 
exchanger) and (2-
way valve) are 
installed in correct 
positions.
1)Correct the instal-
lation.
2)Check resistance of 
thermistors (heat 
exchanger and 2-
way valve).
2)Change the 
specified amount 
of refrigerant.
3)Check the 4-way 
valve for proper 
operation.
3)Replace the 4-
way valve.
4)No abnormality 
found in above 
inspections (1), (2), 
(3).
4)Replace the out-
door unit control 
PWB assembly.
Indoor and 
outdoor 
units do not 
operate.
10-time O O O O O Timer (Orange) 10 0 EEPROM 
error
EEPROM (outdoor) 
data error
-
Replace the outdoor 
unit control PWB 
assembly.
O O Operation (Green)
O Plasmacluster (Blue)
O O O O O Timer (Orange) 1 EEPROM (outdoor) 
data error
O O Operation (Green)
O Plasmacluster (Blue)