14. SELF-CHECK MODE
STEP
LED
P.I. Power Supply
Plasmacluster
Pump
Compressor
Eva Fan
Cond Fan
Louver
(Upper Side)
Louver
(Lower Side)
RED YELLOW GREEN BLUE A B C D A B C D
0
Room Temp Eva Temp Cond Temp Test Input
XXXXXXXXXXXXXX
44.6~107.6°F O 28.4~113.0°F O 28.4~113.0°F O P37 = H O
~44.6°F,
107.6°F~
X
~28.4°F,
113.0°F~
X
~28.4°F,
113.0°F~
X P37 = L X
1
Power On Start
Select
Function Select A Function Select B
X XXOXXXOXOXOXOX
P44 = H O P45 = H O P46 = H O
P44 = L X P45 = L X P46 = L X
2
E
2
PROM
Wireless
Cond Fan RPM
Input
OXOXXX
Speed 1
XOXOXOXO
OK O P40 = H O OK O
NG X P40 = L X NG X
3
Photo Interrupter Float SW (L)
Eva Fan RPM
Input
X OOOX
CL
Speed 2
OPEN X X X X
P64 = H X P63 = H O OK O
P64 = L O P63 = L X NG X
4
Photo Interrupter Float SW (L) Sweat
Auto Restart
Select
XXXX
CM
Speed 3
OPEN OPEN
P64 = H X P63 = H O P41 = H O P34 = H O
P64 = L O P63 = L X P41 = L X P34 = L X
5X X O XXXOO
CH
Speed 4
XXXXXXXX
6 X X X O XXXX
AL
VL
XXXXXXXX
7X O O OXXOX
AM
VM
XXXXXXXX
8 X O O O XXXX
AH
VH
XXXXXXXX
9X O O OXXOX
Mega
VH
XXXXXXXX
10 X O O O XXXXXXXXXX CLOSE
11 X O O O XXOXXX CLOSE CLOSE