E: Not used (Fixed at "0")
F: Customer code F
Prescription 0
Free code 1
G: Opening of customer file during transaction G
In REG & MGR mode 0
In MGR mode 1
H: Price change function H
In REG & MGR mode 0
In MGR mode 1
X: 13 MRS = 00000000
A: Credit totalizer update if RA/PO finalized by Credit
key
A
No 0
Yes 1
B: Separator line in report B
1 line 0
Separator line 1
C, D, E: Not used (Fixed at "000")
F: Treaning the EAN8 code 200 as PLU F
Yes 0
No 1
G: Treatment of the EAN13 code 2xx Dept. or PLU
code printing under SRV#906 a:4 yes
G
PLU code 0
Dept. code 1
H: Price entry after ISBN or ISSN H
Compulsory 0
Inhibited 1
[JOB#2617]
PROGRAMMING OF THE TIME INTERVAL FOR DRAWER ALARM
XXX: 0 ∼ 255 sec
MRS = 000
[JOB#2618]
Scale table programming
X: Table No. = 1~9
YYYY: Weight = 0~99.99
MRS = 00.00
[JOB#2619]
HOURLY REPORT (Starting time)
a: Memory format A
30 minuits (24 hour) 0
15 minuits (12 hour) 1
bb: Starting time (hour): 00 ∼ 23
ex)
Case 1.
X1 Hourly report (#160) (15 min, start time = 7]
2617
TL
XXX
0
X
ST2618 TLX
0
YYYY
X
X
#160
7:00
(DATA)
7:15
(DATA)
7:30
(DATA)
7:45
(DATA)
SUBTOTAL
(DATA)
18:45
(DATA)
SUBTOTAL
(DATA)
12 hours started from 7:00
✱✱
(DATA)
: ✱✱
Data out of range (19:00 to 6:59)