4. FACTORY SETTING
AC power is plug off after shipment setting is done.
Caution
: Do not plug on again after shipment setting is done. If do, please re-do the shipment setting. Do not off with
remote control.
Model Name Factory Setting Key
Name
Remote Control Code S-System Setting OSD Language
Setting
A3KLG1VLZ/J/I/Y/B/N/M
M-Setting 100000001010110 B/G ENGLISH
A3KLG1VLP
P-Setting 100000001011110 M ENGLISH
**Please do inspection for A3KLG1VLP using NTSC signal.
ERUDECORPNOITIDNOCMETI
Factory setting AC power off to exit
the factory setting.
1. Setting is done with test remote control.
2. Press the ‘Factory Setting’ key on the remote control continuously.
3. When Green background appears on screen and ‘K’ mark
disappears, setting is completed.
The followings are initialised to factory setting:
1) User setting
2) Channel data (e.g. broadcast frequencies)
3) Manufacturer’s option settings
4) Password data
5) Setting values are set based on model destination