25
LC-60LE635
LC-60LE638
10. Public Mode (continued)
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
The set contents in the PUBLIC mode are initialized.
It does not exit the PUBLIC mode.
If “EXCUTE” is not executed, the content that does RESET is not reflected.
6. Setting items (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode in setting to “FIXED_ALL” and “FIXED_BODYKEY”, the caution is displayed for 5 seconds.
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2) Instantaneous current shutdown setting in turning off the power [SHUT DOWN MODE]
3) Volume maximum level [MAXIMUM VOLUME]
Option “VARIABLE”, “FIXED_ALL”, “FIXED_BODYKEY” or “RCRESPOND” (loop enabled)
Default “VARIABLE”
Function • VARIABLE
FIXED_ALL
FIXED_BODYKEY
RC RESPOND
: “POWER/RECEPTION” key on TV unit or remote control is enabled.
: “POWER/RECEPTION” key on TV unit or remote control is disabled.
: Only the “MAIN POWER” key on TV unit is disabled (The remote control is enabled).
: The main unit’s POWER switch toggles between ON and Standby (the same operation by the
remote control).
Key disabled when set
other than default
OFF TIMER (SLEEP) (*Only when setting to FIXED_ALL)
Remarks When selecting to “FIXED_ALL”, function related standby factors (see below) doesn't work. and not selecting
OFF TIMER (Sleep)
No operation OFF
No signal OFF (including the power management)
* These items does not exist according to the model.
Option “NORMAL” or “QUICK”
Default NORMAL
Function This function decides whether scanning digital tuner is enabled or disabled when the power is standby.
NORMAL
QUICK
: Scanning digital tuner is enabled when the power is standby.
: Scanning digital tuner is disable
It is possible to put into the standby state instantaneously due to power off input, when the
power is standby.
Immediately, state is a complete standby.
Remarks In selecting “QUICK”, the function does not work for the following items (selection impossible.)
ON TIMER, QUICK START, DIGITAL FIXED, etc.
* These items does not exist according to the model.
Option 0~60 (loop disabled)
Default 60
Function The volume cannot be increased more than the adjusted value (the main unit’s speaker only).
Remarks When setting to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
The volume of the headphones is limited.
The setting is impossible when VOLUME FIXED is set to FIXED.
When power button on the main unit is pressed When power button on R/C is pressed
No Power off by power button.
No Power off by remote control.

Table of Contents

Other manuals for Sharp LC-60LE638E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp LC-60LE638E and is the answer not in the manual?

Sharp LC-60LE638E Specifications

General IconGeneral
BrandSharp
ModelLC-60LE638E
CategoryLCD TV
LanguageEnglish

Related product manuals