EasyManua.ls Logo

Sharp MD-MS701H - Page 25

Sharp MD-MS701H
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD-MS701H/MS702H
– 25 –
: Tracking setting menu
: Tracking system loop filter gain constant setting (normal)
 : setting
: Tracking system loop filter f-characteristics constant 1 setting (normal)
 : setting
: Tracking system loop filter f-characteristics constant 2 setting (normal)
 : setting
: Tracking system filter selection switch setting
 : setting
: Tracking brake level setting (1 line jump)
 : setting
: Tracking brake level setting (10 line jump)
 : setting
: Tracking kick level setting (1 line jump)
 : setting
: Tracking kick level setting (10 line jump)
 : setting
: Tracking drive pulse width time setting (1 line jump)
 : setting
: Tracking drive pulse width time setting (10 line jump)
 : setting
: Tracking slip stop time setting (1 line jump)
 : setting
: Tracking slip stop time setting (10 line jump)
 : setting
: Tracking slip stop time setting (move)
 : setting
: PWM output offset setting
 : setting
: COUT generation comparison level setting (PLAY)
 : setting
COUT generation comparison level setting (REC)
 : setting
Auto-move waiting time setting
 : setting
PLAY
T r a c k
Tracking setting
T G
T F 1
SKIP UP SKIP DOWN
T F 2
SKIP UP SKIP DOWN
T F S
SKIP UP SKIP DOWN
T B o
SKIP UP SKIP DOWN
T B t
SKIP UP SKIP DOWN
T K o
SKIP UP SKIP DOWN
T K t
SKIP UP SKIP DOWN
T D o
SKIP UP SKIP DOWN
T D t
SKIP UP SKIP DOWN
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
* In the specific state pressing the [DISP] key causes change to "focus setting menu".
* In the specific state the setting changes in the range of "00h to FFh"
when the [VOL UP/DOWN] key is pressed.
(The upper limit varies depending on the items)
S C o
SKIP UP SKIP DOWN
S C t
SKIP UP SKIP DOWN
S C m
SKIP UP SKIP DOWN
D B O
SKIP UP SKIP DOWN
C L p
SKIP UP SKIP DOWN
C L r
SKIP UP SKIP DOWN
W T m
SKIP UP SKIP DOWN
: Slide setting menu
: Slide system loop filter gain constant setting
 : setting
: Slide system filter specific constant 2 setting
 : setting
: Slide drive PWM duty limiter setting
 : setting
: Slide serve output dead zone level setting
 : setting
: Slide kick pulse level setting (forced shift)
 : setting
: Slide kick pulse level setting (for 10 lines jump auxiliary)
 : setting
: Slide kick pulse level setting (move)
 : setting
PLAY
S l e d
Slide Setting
S L G
S L 2
SKIP UP SKIP DOWN
S L M
SKIP UP SKIP DOWN
S L V
SKIP UP SKIP DOWN
S K k
SKIP UP SKIP DOWN
S K t
SKIP UP SKIP DOWN
S K m
SKIP UP SKIP DOWN
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
* In the specific state pressing the [DISP] key causes change to "focus setting menu".
* In the specific state the setting changes in the range of "00h to FFh"
when the [VOL UP/DOWN] key is pressed.
(The upper limit varies depending on the items)
: BASS setting menu
: BASS1 characteristics setting
 : setting
: BASS2 characteristics setting
 : setting
: BASS3 characteristics setting
 : setting
PLAY
B a s s
BASS setting
B S 1
B S 2
SKIP UP SKIP DOWN
B S 3
SKIP UP SKIP DOWN
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
* In the specific state pressing the [DISP] key causes change to "focus setting menu".
* In the specific state the setting changes in the range of "00h to FFh"
when the [VOL UP/DOWN] key is pressed.
(The upper limit varies depending on the items)