EasyManua.ls Logo

Sharp MX-5111N - Page 43

Sharp MX-5111N
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SHARP
TEST SIMULATION
43
24
Data Counter & Clear
1
Jam/trouble counter clear
2
Paper feed counter clear
3
Document feed & output counter clear
4
Maintenance counter clear
5
Developer counter clear
6
Copy Counter clear
9
Print & other counter clear
10
Fax counter clear
12
Document filing counter clear
15
Network scanner counter clear
25
Toner usage estimator counter clear
35
Toner cartridge use status clear
25
DV Auto Adjustment & Monitor
1
Toner sensor monitor (Process drive)
2
Auto developer adjustment setting
4
Toner supply quantity data display
5
Toner density correction data display
26
Device Configuration
1
Right Tray setup
2
LCC size set-up
3
Auditor setup
5
A3 Total/Maintenance counter set-up
6
Destination set-up
7
Machine ID setting
10
Network scanner trial mode set-up
18
Toner save operation
30
CE mark control setup
32
Fusing cleaning operation setting
35
Trouble memory mode setting
38
Engine life over setting (Developer)
41
Pamphlet mode AMS operation
49
Copy speed mode setup (Postcard)
50
Function setting: (B/W reverse, Colour
mode, Finisher, Long Size print, Wireless
set etc).
51
Serial port operation setting (PCI)
52
Blank paper count mode setting
53
Enable/Disable auto colour calibration
65
Finisher staple alarm mode set-up
69
Toner near end setting
71
Web Browsing trial mode settings
73
Poster enlargement image loss adjustment
74
OSA trial mode setting
78
Remote operation (VNC) password setting.
79
User data pop up display enable/disable
30
Sensor Operation & Test
1
Main unit sensor check
2
Tray sensor check (main)
40
Bypass Operation & Adjustment
2
Bypass tray width adjustment
7
Bypass tray width detection manual
setting
41
OSS Operation & Adjustment
1
Document sensor operation check
2
Document sensor output setup
3
Document sensor output display
43
Fuser Setting & Adjustment
1
Fuser temperature setup (Paper)
4
Fuser temperature. setup for each mode
20
Fuser temperature. correction for low
temperature & humidity
21
Fuser temp correction for high
temperature & humidity
22
Perform L/L correction for fuser
temperature setting
23
Perform H/H correction for fuser
temperature setting
24
Fuser temperature reset
31
Web cleaning motor operation check.
32
Force operation of web cleaning (job end)
44
Process Control Data
1
Process control mode setting
2
Process control Gain Adjustment
4
Process control initial density setup
6
Process control correction (force)
9
Process control data display
12
DM data, patch/base data display
13
Image density set-up (colour)
14
Fuser temp.& humidity output data
15
OPC drum idle rotation setting
21
Half tone process control registration
22
Half tone process control patch result
24
Half tone correction data result display
25
Initial half tone correction data display
26
Half tone process control execution
27
Half tone process control correction clear
28
Process control timing (On/Off) setting

Other manuals for Sharp MX-5111N