3
TIPS
Controlling the Monitor with a computer (LAN)
You can control this monitor from a computer via network.
This monitor must be connected to a network.
Set "LAN Port" to ON in "ADMIN" > "COMMUNICATION
SETTING" on the Setting menu and configure network
settings in "LAN SETUP".
Set "COMMAND (LAN)" to ON in "ADMIN" >
"CONTROL FUNCTION" on the Setting menu.
The settings for the commands are set in
"NETWORK - COMMAND" on the web page.
Command-based control
You can control the monitor using S-Format
commands (see page 5) via terminal software and
other appropriate applications.
Read the manual for the terminal software for
detailed instructions.
Command setting for normal
communication
You can control user access by setting a login name and
password.
(1) Set ADMIN> CONTROL FUNCTION>
HTTP SERVER to ON.
(2) Press the INFORMATION button and check
the IP address of the monitor in Product
Information 2.
(3) Input the address in the Web browser, then
login page is displayed.
(4) Login as Administrator. USER NAME: admin /
PASSWORD: {default: Value registered when
the power was turned on for the first time}
(5) Select NETWORK-COMMAND in the side
menu.
(6) Set COMMAND-CONTROL to ENABLE
(7) Set SECURE PROTOCOL to DISABLE
(default).
(8) Set LOGIN AUTHENTICATION (S-FORMAT)”
to ENABLE (default).
(9) Press APPLY button.
Command control via normal
communication.
(1) Connect the computer to the monitor.
1. Specify the IP address and data port number
(Default setting: 10008) and connect the
computer to the monitor.
When connection has been established
successfully, [Login: ] is returned as response.
2. Send the user name.
Send [user name] + [ ].
When the transmission is successful,
[ Password: ] is returned as response.
3. Send the password.
Send [password] + [ ].
If the password is not set, send [ ].
When the transmission is successful, [OK
] is returned as response.
(2) Send commands to control the monitor.
The commands used are the same as those for
RS-232C. Refer to the communication
procedure (see page 4) for operation.
Usable commands are provided in S-Format
command table (see page 5).
(3) Disconnect the connection with the monitor
and quit the function.
1. Send [BYE ].
When the transmission is successful, [Goodbye
] is returned and the connection is disconnected.
You can access by settings of user name and password
registered in USER NAME / PASSWORD. Default user
name are “user1” or “user2”. Default password is the
value that registered when the power was turned on for
the first time.
When access control is not used, set [LOGIN
AUTHENTICATION (S-FORMAT)] to DISABLE. In this
case send [blank] + [ ] as user name and password.
If "AUTO LOGOUT" is on, the connection will be
disconnected after 15 minutes of no command
communication.
Up to 3 connections can be used at the same time.
TIPS

Related product manuals